Configuring the Shelf
121
To display the Shelf Configuration menu, select
[0] Shelf
from the List Card menu.
Figure 82
Shelf Configuration Menu
The Shelf Configuration menu displays the following information about the shelf:
n
Hardware revision
n
Serial number
n
Power supply status (in service or out of service) for power supplies 1-6
n
External alarm status (normally open or normally closed) for external alarms 1-3
Setting Power Supply
Status
To set the status of a power supply, follow these steps:
1
From the List Card menu, shown earlier in Figure 81, select
[0] Shelf
to open the
Shelf Configuration menu, shown earlier in Figure 82.
2
Enter the number corresponding to the power supply that you want to set. The
following prompt appears:
Enter Power Supply (1= Out of Service, 2= In Service):
3
Enter
1
to take the power supply out of service or
2
to put the power supply
into service.
Setting External Alarm
Status
The PathBuilder S700 supports up to three alarms from outside equipment. To set
the external alarms, follow these steps:
1
From the List Card menu, shown earlier in Figure 81, select
[0] Shelf
to open the
Shelf Configuration menu, shown earlier in Figure 82.
2
Enter the number corresponding to the external alarm that you want to set (
7
for
alarm #1,
8
for alarm #2, or
9
for alarm #3).
The following prompt appears:
Enter External Alarm 1 (1= Normally Open, 2= Normally Closed)
3
Enter
1
to set the alarm to normally open or
2
to set the alarm to normally closed.
For details about how to connect the external alarms, see “Connecting the Office
Alarms” in Chapter 2.
Содержание 3C63400-3AC-C - PathBuilder S700 Switch
Страница 14: ...xiv CHAPTER SUPPLEMENTARY REGULATORY INFORMATION ...
Страница 18: ...4 ABOUT THIS GUIDE ...
Страница 28: ...14 CHAPTER 1 SYSTEM DESCRIPTION ...
Страница 88: ...74 CHAPTER 3 GETTING STARTED ...
Страница 260: ...246 CHAPTER 6 PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING ...
Страница 270: ...256 INDEX ...