Configuring OC3/STM-1 UNI Modules
129
Figure 90
OC3/STM-1 UNI Configuration Menu
2
Configure the OC3/STM-1 card.
a
Select
[1] Card Information
to display the OC3/STM-1 UNI Card Configuration
menu, shown in Figure 91. This menu displays the current configuration for the
OC3/STM-1 UNI module and provides options for changing certain parameters.
Figure 91
OC3/STM-1 UNI Card Configuration Menu
b
Set the following parameters as desired:
Admin Status
—Administrative Status:
In Service
or
Out of Service
.
Sonet Interface Mode
—Synchronous Optical Network mode:
OC3
or
STM-1
.
OC3
(SONET) is a high-speed synchronous system technology used on
fiber-optic cable networks.
STM-1
(SDH or Synchronous Digital Hierarchy) is the
European equivalent of SONET.
ATM Payload Scramble
—Enables (
Yes
) or disables (
No
) payload scrambling
for the OC3/STM-1 port. Payload scrambling scrambles the 48-byte payload in
outgoing cells in a defined manner and unscrambles the payload in incoming