The IMA Link Status screen lists the following information pertaining to the IMA
status of an individual link in an IMA group.
NE Tx State
—Near-end transmit state in the interworking link state machine.
Table 34 lists the possible link states.
NE Rx State
—Near-end transmit state in the interworking link state machine.
Table 34 lists the possible link states.
FE Tx State
—Far-end transmit state in the interworking link state machine.
Table 34 lists the possible link states.
FE Rx State
—Far-end transmit state in the interworking link state machine.
Table 34 lists the possible link states.
.
FE Rx Failure
—Far-end Rx failure status in the interworking link state machine.
Table 35 lists the possible IMA link failure status conditions.
NE Rx Failure
—Near-end Rx failure status in the interworking link state machine.
Table 35 lists the possible IMA link failure status conditions.
Tx LID
—Transmit logical link ID: 0-31. This number reflects the local IMA ID.
Rx LID
—Receive logical link ID: 0-31. This number reflects the remote IMA ID.
Operation LInk Delay
—The differential link delay referenced to the fastest link in
the same group.
Table 34
Possible IMA Link States
State
Tx Condition
Rx Condition
not in group
This link is not part of the IMA
group.
This link is not part of the IMA
group.
unusable
blocked
This is caused by LOS, which
would result in back clock from
the framer if the port is in
looped timing.
This is caused by AFA,
excessive delay, or mismatched
protocol.
usable
This link is ready to pass data.
This link is ready to pass data.
active
This link is passing data.
This link is passing data.
Table 35
Possible IMA Link Failure Status Conditions
Failure
Description
link failure
This is caused by LOS, AIS, OOF, or LCD
LIF failure
This is caused by LIF
LODS failure
This is caused by LODS.
Misconnected
This is caused by bad IMA ID, bad link ID, or bad SCCI.
blocked
This is caused by AFA, excessive delay, or mismatched
protocol.
fault
This is caused by bad M value, bad symmetry, bad offset,
or duplicate link ID.
far end Tx link
unusable
This is caused by the far end reporting Tx unusable in the
ICP cells.
far end Rx link
unusable
This is caused by the far end reporting Rx unusable in the
ICP cells.
no failure
The link has no failure.
Содержание 3C63400-3AC-C - PathBuilder S700 Switch
Страница 14: ...xiv CHAPTER SUPPLEMENTARY REGULATORY INFORMATION ...
Страница 18: ...4 ABOUT THIS GUIDE ...
Страница 28: ...14 CHAPTER 1 SYSTEM DESCRIPTION ...
Страница 88: ...74 CHAPTER 3 GETTING STARTED ...
Страница 260: ...246 CHAPTER 6 PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING ...
Страница 270: ...256 INDEX ...