Viewing and Configuring System Information
115
2
Enter
y
to update the flash file system.
The user configuration data is automatically saved into flash memory every
minute. I there is a system failure (a power failure, for example), any changes that
you make during the auto-saving interval will be lost. Thus, we recommend that
you use the
[12] Update Flash File System
option, as described above, immediately
after you make major configuration changes.
Resetting the Interface
Card
To reset any PathBuilder S700 module, follow these steps:
If you reset the interface card, you will terminate your Telnet session.
1
From the System Administration menu, select
[10] Reset Interface Card
. The
following prompt appears:
Which slot to reset (1-18)?
2
Enter the number of the slot in which the card you want to reset is installed. The
following prompt appears:
Are you sure you want to reset this card (Y/N) [N]?
3
Enter
y
to reset the card.
Viewing an Equipment
List
To view information about the modules currently installed on your PathBuilder
S700:
From the System Administration menu, select
[11] Show Equipment List
. Figure 79
shows a sample Equipment List.
Figure 79
Equipment List
The Equipment List displays the following information for each installed module:
SLOT
—A reference number for the ports on the motherboard. This number
corresponds to the number on the List Card menu. (See Figure 78, later in this
chapter.)
Содержание 3C63400-3AC-C - PathBuilder S700 Switch
Страница 14: ...xiv CHAPTER SUPPLEMENTARY REGULATORY INFORMATION ...
Страница 18: ...4 ABOUT THIS GUIDE ...
Страница 28: ...14 CHAPTER 1 SYSTEM DESCRIPTION ...
Страница 88: ...74 CHAPTER 3 GETTING STARTED ...
Страница 260: ...246 CHAPTER 6 PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING ...
Страница 270: ...256 INDEX ...