Chapter 31 Auto PD Recovery
XGS2220 Series User’s Guide
211
Figure 151
Auto PD Recovery (Ping Mode)
Figure 152
Auto PD Recovery (LLDP Mode)
2
Select the desired ports in the
Active
column.
3
Select the
Mode
.
When you select
Ping
, the connected PD’s IPv4 or IPv6 address to which the Switch sends ping requests
will display automatically if the PD supports LLDP. If not, enter the IP address of the PDs in the
Neighbor IP
field.
The default setting for
Polling Interval (sec)
(20 secs) and
Polling Count
(3 times) will cause the Switch to
ping the PD status every 20 seconds. If there is no ping reply from the PD,
Polling Count
starts to count
from 1. Once
Polling Count
reaches 3, the Switch will cause a
Reboot-Alarm
on the PD as selected in
Action
.
When you select
LLDP
, the Switch monitors the PD status by checking incoming LLDP packets every 30
seconds from the PD (default value of transmit interval for LLDP feature).
Likewise, the Switch sends out LLDP packets to the PD every 30 seconds to update the
MONITOR
>