Fade Time Commands – Editing Cues
The following commands can be used to globally edit the fade times of parameters in
existing cues:
S/C TIME X ENTER
Sets the fade times for all fixture parameters to X
seconds.
S/C TIME U/D ENTER
Sets the intensity fade up and fade down times to U
and D seconds respectively.
S/C TIME COLOUR X ENTER
Sets the fade times for all colour parameters to X
seconds
S/C TIME BEAM X ENTER
Sets the fade times for all beamshape parameters to X
seconds.
S/C TIME POSITION X ENTER
Sets the fade times for all position parameters to X
seconds.
S/C TIME U/D COLOUR X BEAM Y
POSITION Z ENTER
Sets the intensity fade up and fade down times to U
and D, the colour fade times to X, the beamshape fade
times to Y and the position fade times to Z.
Note – Fade and Delay Times
The fade and delay times for all parameters programmed in a cue can also be globally
edited from the Cue Stack Window.