![YOKOGAWA AE100D Instruction Manual Download Page 246](http://html.mh-extra.com/html/yokogawa/ae100d/ae100d_instruction-manual_911083246.webp)
IM 1F6A0-01E
9-6
9. EXPLOSION PRTECTED TYPE INSTRUMENT
9.2.6
Data Plate
AMB.TEMP.: -29 to 60
C
TEMP.CODE:T6, NEMA 4X
EXPLOSIONPROOF
CLI,DIV1,GPS A,B,C&D;
MWP
3UC
10.5 to 42V DC
STYLE
MODEL
SUFFIX
SUPPLY
K-FACTOR
OUTPUT
RANGE
NO.
TAG NO.
VORTEX FLOWMETER
WARNING
!
SEAL ALL CONDUITS WITHIN 18 INCHES
DUST-IGNITIONPROOF
CLII/III,GPS E, F&G
APPROVED
FM
THE INSTRUCTION MANUAL IM 1F6A0-01E
OPEN CIRCUIT BEFORE REMOVING COVER.
MWP
3UE
10.5 to 42V DC
STYLE
MODEL
SUFFIX
SUPPLY
K-FACTOR
OUTPUT
RANGE
NO.
TAG NO.
VORTEX FLOWMETER
WARNING
!
APPROVED
FM
SUBSTITUTION OF COMPONENTS MAY IMPAIR
INTRINSIC SAFETY. INSTALL IN ACCORDANCE
WITH DOC. NO. IFM019-A12 P1 & 2.
SUBSTITUTION OF COMPONENTS MAY IMPAIR
INTRINSIC SAFETY. INSTALL IN ACCORDANCE
WITH DOC. NO. IFM019-A12 P1 & 2.
SUBSTITUTION OF COMPONENTS MAY IMPAIR
INTRINSIC SAFETY. INSTALL IN ACCORDANCE
WITH DOC. NO. IFM019-A12 P1 & 2.
MWP
3UE
STYLE
MODEL
SUFFIX
K-FACTOR
RANGE
NO.
TAG NO.
VORTEX FLOWMETER
WARNING
!
APPROVED
FM
WHEN INSTALLED IN DIV.2 ,SEALS NOT REQUIRED.
INSTALL IN ACCORDANCE WITH
THE INSTRUCTION MANUAL IM 1F6A0-01E
OPEN CIRCUIT BEFORE REMOVING COVER.
INSTALL IN ACCORDANCE WITH
AMB.TEMP.: -29 to 60
C
TEMP.CODE:T6, NEMA 4X
EXPLOSIONPROOF
CLI,DIV1,GPS A,B,C&D;
SEAL ALL CONDUITS WITHIN 18 INCHES
DUST-IGNITIONPROOF
CLII/III,GPS E, F&G
WHEN INSTALLED IN DIV.2 ,SEALS NOT REQUIRED.
AMB.TEMP.: -40 to 60
C
TEMP.CODE:T6 NEMA 4X
EXPLOSIONPROOF
CLI,DIV1,GPS A,B,C&D;
3YC
10.5 to 42V DC
STYLE
MODEL
SUFFIX
SUPPLY
K-FACTOR
OUTPUT
RANGE
NO.
TAG NO.
VORTEX FLOW CONVERTER
WARNING
!
SEAL ALL CONDUITS WITHIN 18 INCHES
DUST-IGNITIONPROOF
CLII/III,GPS E, F&G
APPROVED
FM
THE INSTRUCTION MANUAL IM 1F6A0-01E
OPEN CIRCUIT BEFORE REMOVING COVER.
WHEN INSTALLED IN DIV.2 ,SEALS NOT REQUIRED.
INSTALL IN ACCORDANCE WITH
4 to 20mA DC / PULSE
INTRINSICALLY SAFE FOR CL
1
,
2
,
3
,
DIV 1, GPS A,B,C,D,E,F&G, T4
AND CL
1
, ZONE 0. AEx ia
2
C T4
NONINCENDIVE FOR CL
1
,
2
, DIV 2,
GAS A,B,C,D,F&G, CL
3
, DIV 1, T4,
AND CL
1
, ZONE 2 GP
2
C, T4
AMB. TEMP. : -40 to 60
C NEMA 4X
Vmax = 30V, Imax = 165mA, Pi = 0.9W, Ci = 12nF, Li = 0.15mH
INTRINSICALLY SAFE FOR CL
1
,
2
,
3
,
DIV 1, GPS A,B,C,D,E,F&G, T4
AND CL
1
, ZONE 0. AEx ia
2
C T4
NONINCENDIVE FOR CL
1
,
2
, DIV 2,
GAS A,B,C,D,F&G, CL
3
, DIV 1, T4,
AND CL
1
, ZONE 2 GP
2
C, T4
AMB. TEMP. : -29 to 80
C NEMA 4X
INTRINSICALLY SAFE FOR CL
1
,
2
,
3
,
DIV 1, GPS A,B,C,D,E,F&G, T4
AND CL
1
, ZONE 0. AEx ia
2
C T4
NONINCENDIVE FOR CL
1
,
2
, DIv 2,
GAS A,B,C,D,F&G, CL
3
, DIV 1, T4,
AND CL
1
, ZONE 2 GP
2
C, T4
AMB. TEMP. : -29 to 60
C NEMA 4X
Vmax = 30V, Imax = 165mA, Pi = 0.9W, Ci = 12nF, Li = 0.15mH
3UE
10.5 to 42V DC
STYLE
MODEL
SUFFIX
SUPPLY
K-FACTOR
OUTPUT
RANGE
NO.
TAG NO.
VORTEX FLOW CONVERTER
WARNING
!
APPROVED
FM
Integral Type Converter
4 to 20mA DC / PULSE
N200
N200
N200
N200
N200
N200
Integral Type Flowmeter
Remote Type Flowmeter
Explosion Proof
Intrinsically safe
Integral Type Flowmeter
Remote Type Flowmeter
MPa at 38
C
4 to 20mA DC / PULSE
MPa at 38
C
4 to 20mA DC / PULSE
MPa at 38
C
F090206.EPS
MWP
3WC
STYLE
MODEL
SUFFIX
K-FACTOR
RANGE
NO.
TAG NO.
VORTEX FLOWMETER
WARNING
!
APPROVED
FM
MPa at 38
C
Remote Type Converter
9.3
SAA (Now Prepairing)
WARNING
Only trained persons use this instrument in industrial
locations.
9.3.1
Technical Data
• Flameproof
Exd IIC T6....T1, IP67, Class I, Zone I.
Ambient Temperature
: -40 to +60
°
C
Max. Process Temp.
: T6; 85
°
C, T5; 100
°
C,
T4: 135
°
C, T3; 200
°
C,
T2; 300
°
C, T1; 450
°
C
Electrical Connection
: ANSI 1/2 NPT female,
ISO M20
X
1.5 female
• Intrinsically Safe
Type of Protection: Ex ia IIC T4...T1 IP67(Integral Type
Flowmeter and Remote Type Flowmeter)
Ex ia IIC T4 IP67 (Remote Type Converter)
Hazardous Area: Class I, Zero 0 (Integral Type Flowmeter
and Remote Type Converter)
Maximum Input Voltage (Ui)=30V
Maximum Input Current (Ii)=165mA
Maximum Input Power (Pi)=0.9W
Internal Capacitance (Ci)=6nF
Internal Inductance (Li)=0.15mH
Type of Protection: Ex n IIC T4...T1 IP67 (Integral Type
Flowmeter and Remote Type Flowmeter)
Ex n IIC T4 IP67 (Remote Type Converter)
Hazardous Area: Class I, Zone 2
Maximum Input Voltage (Ui)=30V
Ambient Temperature: -40
°
C to +60
°
C (Integral Type
Flowmeter and Remote Type
Converter)
-40
°
C to 80
°
C (Remote Type
Flowmeter)
Ambient Humidity: 0 to 100% RH (No condensation)
(Integral Type Flowmeter)
Ambient Temperature Process Temperature
60
°
C
135
°
C
60
°
C
200
°
C
60
°
C
300
°
C
60
°
C
450
°
C
T4
Temperature Class
T3
T2*
T1*
T090301.eps
*: Use /HT version above 260
°
C