![YOKOGAWA AE100D Instruction Manual Download Page 157](http://html.mh-extra.com/html/yokogawa/ae100d/ae100d_instruction-manual_911083157.webp)
IM 1F6A0-01E
2-8
2. GENERAL DESCRIPTION
Down-scale burn-out in CPU or
EEPROM failure (Note 3)
Set output 3.6mA or less when burn-out occurred.
DY***-D,E / DYA
C1
Item
Specification
Code
Stainless Steel Tag Plate (Note 1)
Stainless Steel Bolt & Nut Assembly
Degrease Treatment (Note 2)
Static Pressure and Leakage Test
Certificate
High Process Temperature Version
Cryogenic Version
Paint Color Change
Epoxy Coating
SUS304 tag plate, hung on converter case.
SUS304 bolt/nut assembly.
Used when a wafer type is installed.
All wetted parts are assembled after degreasing for stainless body.
After flow calibration, the body is cleaned by trichloroethylene.
Using hydraulic or nitrogen pressure according to the table 4.
Test time is 10 minutes. Available for the general type.
This specification temperature is from -40 to +450
°
C
Refer to Table 1 , Figure 4.
Refer to Table 5 for minimum velocity.
In case of another size, please contact to YOKOGAWA sales person.
This specification temperature is from -200 to +100
°
C
Refer to Table 1 , Figure 5.
In case of another size, please contact to YOKOGAWA sales person.
Only for converter covers: See refer to Table.3.
Epoxy coating for meter cover and case.
SCT
BL
Stainless Steel Bracket for Remote
Conveter (DYA)
The bracket material for remote converter type (DYA) is SUS304.
GOST Certificate (Note 4)
Calibration Certificate for GOST(only for products produced at YFT)
There is an arrester inside converter for power supply line.
Maximum power supply voltage : 30VDC
Lightning Protector
Compliance with NACE. Refer to Table 1.
Compliance with NACE
Compliance with NAMUR43. Current signal for measurement is 4mA up to
20.5mA. Set output 3.6mA or less when burn-out occurred.
Compliance with NAMUR
NM
Applicable Model
See Table3
T01
K1
X1
HT
LT
SB
GOS
A
NC
DY
Wafer Type
DY/DYA
Multi-Variable Type
Build in thermometer sensor(Pt 1000) in vortex shedder bar
MV
DY/DYA
DY / DYA
DYA
DY***-D,E / DYA
DY
DY / DYA
Anti-corrosion Version I. Refer to Table 1.
Anti-corrosion Version I
HX
DY
Anti-corrosion Version II
Anti-corrosion Version II. Refer to Table 1.
HY
DY
DY
DY
DY / DYA
DY***-N
DY***-N
DY / DYA
Converter Installing Direction 180
°
Change (Note 5)
Converter installing direction 180
°
change inversely when shipped.
DY
CRC
Flameproof Packing Adapter
Power source connection port and signal cable (remote type) connection port.
JIS G1/2 female thread. Other cable shape: ø 8 to ø 12.
G11 : One piece, G12 : Two pieces.
G11
G12
DY / DYA
T020403.EPS
Calibration Certificate
Level 2
Declaration and Calibration Equipment List
Level 3
Declaration and Primary Standard List
Level 4
Declaration and YOKOGAWA Measuring
L2
DY / DYA
L3
DY / DYA
L4
DY / DYA
Hydrostatic Pressure Test Certificate
T02
DY
Using hydrostatic pressure according to table 5.
Test time is 10 minutes. Available for the general type.