![YOKOGAWA AE100D Instruction Manual Download Page 219](http://html.mh-extra.com/html/yokogawa/ae100d/ae100d_instruction-manual_911083219.webp)
IM 1F6A0-01E
6-8
6. PARAMETERS
(9) Item K : Maintenance
These items are for maintenance.
T060209.EPS
K00
K10
K20
K25
K26
K30
K32
K34
K36
K38
K40
K45
K50
K60
W
W
W
R / W
R
R
R
R
R
R
W
R
R
m/s
m/s
Hz
Hz
D25
1.0
1.0
(0)
D
D
D
D
D
D
D
D
D
MAINTENANCE
TLA
SIGNAL LEVEL
N.B. MODE
NOISE RATIO
VELOCITY
SPAN V
VORTEX FREQ.
SPAN F
DENSITY
ERROR RECORD
H VIBRATION
SOFTWARE REV
SELF CHECK
0.1 to 20.0
0.1 to 20.0
AUTO (0)
MANUAL (1)
TUNING AT ZERO (2)
0.00 to 2.00
0.00001 to 32000
0%
No ACTION
0.01 to 99.99
GOOD
ERROR
Menu K (Maintenance)
Trigger Level Adjust
Signal Level
Selection of Noise balance Mode
Velocity
Span velocity
Vortex frequency
Span frequency
Density value (Calculated by Thermometer)
Error Records
Selection of Output Function when “High
Vibration” error is indicated.
Software Revision Number
Self-diagnostic message
Item
Name
R / W
Data Range
Unit
Remark
Initial
value
Disp. U / D
(Indicate only for F10: “Saturated Steam” or “Super heat steam” or “Liquid mass)(*1)
(*1) Only for Option Code /MV
(10) Item M : Memo
These items are for Memorandum.
T060210.EPS
M00
M10
M20
M30
M60
W
W
W
R
MEMO
MEMO 1
MEMO 2
MEMO 3
SELF CHECK
16 characters
16 characters
16 characters
GOOD
ERROR
Menu M (Memo)
Memorandum 1 (16 characters)
Memorandum 2 (16 characters)
Memorandum 3 (16 characters)
Self-diagnostic message
Item
Name
R / W
Data Range
Unit
Remark
Initial
value
Disp. U / D