10. OUTLINE
IM 1E7B0-02E
10-1
STANDARD SPECIFICATIONS
Note 1: For models with no indicator, a hand-held
terminal is necessary to set parameters.
Note 2: Pulse output, status output and alarm output use
common terminals, therefore, these functions are
not available at the same time.
Note 3: Please refer to GS 01E07F01-00E for Fieldbus
communication type(/FB).
Excitation method: Dual frequency excitation
Output Signal(Note 3):
Current Output: 4 to 20 mA DC (Load resistance 750
Ω
maximum).
Transistor Contact Output(Open-collector):
Pulse, alarm or status output selected by
parameter setting. Contact rating: 30 V DC
(OFF), 200 mA (ON).
Communication (option)(Note 3):
BRAIN or HART (Superimposed on the 4 to 20 mA DC
signal)
Load Resistance: (including cable resistance)
BRAIN:
250 to 600
Ω
HART:
230 to 600
Ω
, depending on q’ty of field
devices connected to the loop (multidrop
mode)
Load Capacitance: 0.22
µ
F maximum
Load Inductance: 3.3 mH maximum
Distance from Power Line:
15 cm(0.6 ft) or more (Parallel wiring should
be avoided.)
Input Impedance of Receiver Connected to the Receiv-
ing Resistance: 10k
Ω
or larger (at 2.4 kHz)
Maximum Cable Length:
2 km (6500 ft) (when polyethylene-insulated
PVC-sheathed control cables (CEV cables)
are used)
Note: HART is a registered trademark of the HART
Communication Foundation.
Instantaneous Flow Rate Display Function:
Flow rate can be displayed either in engineer-
ing units or in percent of span.
(for models with indicator)
Totalizer Display Function:
Totalized volume in any engineering unit can
be displayed by setting a totalizing factor. (for
models with indicator)
Damping Time Constant(Note 1):
Settable from 0.1 second to 200 seconds
(63% response time).
Span Setting Function(Note 1):
Volumetric flow setting is available by setting
volume unit, time unit, flow rate value and
flow tube size.
Volume Unit: gallon(US), m
3
, l (litre), cm
3
,
barrel(=158.987L)
Velocity Unit: ft, m
Time Unit: sec., min., hour, day
Flow Tube Size: inch, mm
Pulse Output Function(Note 2), (Note 3):
Scaled pulse can be output by setting a pulse
factor.
Pulse Width: Duty 50% or fixed pulse width (0.5, 1, 20,
33, 50, or 100 ms) - user selectable.
10. OUTLINE
Output Rate: 0.0001 to 1000pps (when pulse output
function is selected.)
Status Output Function(Note 2), (Note 3):
One of the following is selected by parameter
setting.
• Auto 2 Ranges Status Output:
Indicates the selected range for automatic
dual range function.
• Forward and Reverse Status Output:
Indicates the flow direction for forward and
reverse flow measurement mode.
• Totalization Status Output:
Indicates that the internal totalized value
exceeds the set value.
• Low Limit Alarm:
Indicates that flow rate is under the low limit
set value.
Alarm Output Function(Note 2), (Note 3):
Indcates that an alarm occurs
(Normal Close Fixed).
Self Diagnostics Function(Note 1):
Converter failure, flow tube failure, erroneous
setting, etc. can be diagnosed and displayed.
Data Security During Power Failure:
Data storage by EEPROM - no back-up
battery required.
Electrical Connection:
ANSI 1/2NPT female, DIN Pg13.5 female,
ISO M20
×
1.5 female, JIS G1/2 female.
Terminal Connection: M4 size screw terminal.
Case Material: Aluminum alloy.
Coating:
Polyurethane corrosion-resistant coating.
Cover; Deep sea moss green (Munsell
0.6GY3.1/2.0)
Case; Frosty white (Munsell 2.5Y8.4/1.2)
Degrees of Protection: IP67, NEMA 4X, JIS C0920
water tight protection
Size:
• General Purpose Type
Size in mm
(inch)
Lining
PFA
Ceramic
Polyurethane
T01.EPS
2.5(0.1), 5(0.2),
10(0.4), 15(0.5),
25(1), 40(1.5),
50(2), 80(3),
100(4), 150(6),
200(8)
25(1), 40(1.5),
50(2), 80(3),
100(4), 150(6),
200(8), 250(10),
300(12),
350(14), 400(16)
2
.5(0.1), 5(0.2),
10(0.4), 15(0.5),
25(1), 40(1.5),
50(2), 65(2.5),
80(3), 100(4),
125(5), 150(6),
200(8), 250(10),
300(12), 350(14),
400(16)
• Explosion Proof Type
Size in mm
(inch)
Lining
PFA
Ceramic
T02.EPS
2.5(0.1), 5(0.2), 10(0.4),
15(0.5), 25(1), 40(1.5),
50(2), 65(2.5), 80(3),
100(4), 125(5), 150(6),
200(8), 250(10)*,
300(12)*, 350(14)*,
2.5(0.1), 5(0.2), 10(0.4),
15(0.5), 25(1), 40(1.5),
50(2), 80(3), 100(4),
150(6), 200(8)
400(16)*
*250 to 400mm with flange connection are only for CENELEC ATEX
or SAA.
250 and 300mm with wafer connection are only for general
purpose use.
*65 and 125mm are only for CENELEC ATEX.