6. PARAMETERS
(5) Item E (METER SETUP)
These items are for detector set up that has already been set
before shipment.
A value in “( )” is the data corresponding to indicator.
[E10:NOMINAL SIZE] Nominal size of the
detector
Select the nominal size of the flowmeter, from “15mm(0),
25mm(1), 40mm(2), 50mm(3), 80mm(4), 100mm(5),
150mm(6), 200mm(7), 250mm(8), 300mm(9)”
[E20:BODY TYPE] Body type for the detector
Select body type for detector from standard or high pressure.
[E30:SENSOR TYPE] Sensor type for the
detector
Select sensor type for the detector from standard or HT/LT
[E40:K-FACTOR UNIT],
Select this unit from p/l, p/Usgal, p/Ukgal.
[E41:K-FACTOR]
The flowmeter data plate includes a K-factor (KM) at 15
°
C
for the combined detector.
[E50:DETECTOR NO.] Detector number of
flowmeter
Set the serial number using 16 alphanumeric characters of the
detector combined converter.
(6) ltem F (Thermometer)
These items are for setting of thrmometer and available when
build in thermometer type (Option code: /MV).
[F10: Function] Thermometer function
Select the thermometer function.
Monitor only(0):
Only temperature measurement.
Saturated Steam:
Mass Flow rate is calculated from density
values by temperature measurement
using saturated steam table.
Superheat Steam: Mass Flow rate is calculated from density
values by temperature measured by using
steam table. In order to measure
superheat steam. It is necessary to make
canstant pressure value.
GAS: STD/Normal: Volumetric flow rate at standard
condition is calculated by using Pressure-
Temperature correction. It is necessary to
male constant pressure value.
Liquid: Mass:
Mass flow rate is calculated by using the
density change values depend on
temperature values by which the
secondary order function is used.
The following item should be done in case of
which F10 is Saturated steam
[F12 MASS UNlT] Mass flow unit
Select mass rate unit from kg(0), t(1), Ib(2), k
ᐉ
b(3).
The following items should be done in case of
which F10 is Superheat steam
[F14 PRESS UNIT] Pressure unit
Select pressure unit from MPa abs(0), kPa abs(1), bar abs(2),
kg/cm
2
a(3), psia(4).
[F15 PRESS f] Pressure value
Set absolute pressure values at operating condition.
[F16 MASS UNIT] Mass flow unit
Select mass flow unit from kg(0), t(1),
ᐉ
b(2), k
ᐉ
b(3).
The following items should be done in case of
which F10 is GAS: STD/Normal
[F18 TEMP UNIT] Temperature unit
Select temperature unit from deg C(0), deg F (1).
[F19 TEMP b] Temperature b
Set tempareture value at nomal/standard condition.