Administrator’s Guide for W80 DECT IP Multi-Cell System
110
Permitted
Values
0
-Disabled
1
-Enabled
Default
1
Web UI
Features > Alarm > Edit > Stop Alarm From Handset
Parameter
alarm.X.trigger_delay
[1]
<y0000000000xx>.cfg
Description
It configures the delay time (in seconds) to trigger the alarm from the handset.
Permitted
Values
Integer from 1 to 7200
Default
3
Web UI
Features > Alarm > Edit > Trigger Delay
Parameter
alarm.X.pre_alarm.handset_stop.enable
[1]
<y0000000000xx>.cfg
Description
It enables or disables to stop the pre-alarm (reminder before the alarm) from the handset.
Permitted
Values
0
-Disabled
1
-Enabled
Default
1
Web UI
Features > Alarm > Edit > Stop Pre-Alarm From Handset
Parameter
alarm.X.pre_alarm.delay
[1]
<y0000000000xx>.cfg
Description
It configures the pre-alarm time (in seconds) of the handset.
Permitted
Values
Integer from 0 to 7200
Default
0
Web UI
Features > Alarm > Edit > Pre-Alarm Delay
Parameter
alarm.X.ring.enable
[1]
<y0000000000xx>.cfg
Description
It enables or disables to play the ringtone when the handset initiates the pre-alarm.
Permitted
Values
0
-Disabled
1
-Enabled
Default
1
Web UI
Features > Alarm > Edit > Ring
Parameter
alarm.X.weekly.begin_time
[1]
alarm.X.weekly.end_time
[1]
<y0000000000xx>.cfg
Description
It configures the starting / ending time of the day for the handset to perform an alarm detection.
The alarm detection occurs on a random time between the starting time and the ending time.
Note
: If the configured starting time is greater than the ending time, such as 23:00-06:00, it means that
the alarm detection is enabled on the day from 00:00-06:00 and 23:00-00:00.
Permitted
Values
Time from 00:00 to 23:59