Administrator’s Guide for W80 DECT IP Multi-Cell System
106
Permitted
Values
String within 32 characters
Default
var
Parameter
static.security.user_password
<y0000000000xx>.cfg
Description
It configures the password.
The phone uses “user” as the default user password, "var" as the default var password and “admin” as
the default administrator password.
The valid value format is <username>:<new password>.
Example
:
static.security.user_password = user:123 means setting the password of user to 123.
static.security.user_password = admin:456 means setting the password of administrator to 456.
static.security.user_password = var:789 means setting the password of var to 789.
Note
: The phones support ASCII characters 32-126(0x20-0x7E) in passwords. You can set the pass-
word to be empty via the web user interface only.
Permitted
Values
String within 32 characters
Default
Blank
Web UI
Security > Password
User Access Level Configuration
For more information, refer to
Yealink SIP IP Phones Configuration Guide for User Access Level
.
The following table lists the parameters you can use to configure the user access level.
Parameter
static.security.var_enable
[1]
<y0000000000xx>.cfg
Description
It enables or disables the 3-level access permissions (admin, user, var).
Permitted
Values
0
-Disabled
1
-Enabled
Default
0
Parameter
static.web_item_level.url
[1]
<y0000000000xx>.cfg
Description
It configures the access URL of the file, which defines 3-level access permissions.
Permitted
Values
URL within 511 characters
Default
Blank
Parameter
static.security.default_access_level
[1]
<y0000000000xx>.cfg
Description
It configures the default access level to access the handset user interface.
Note
: It works only if “static.security.var_enable” is set to 1 (Enabled).
Permitted
Values
0
-user
1
-var
2
-admin
Default
0