Event ID
Description
1: STOP (update)
2: STOP (memory reset)
3: STOP (auto initialization)
4: STOP (internal)
5: STARTUP (cold start)
6: STARTUP (restart/warm start)
7: STARTUP (hot restart)
9: RUN
10: HALT
11: COUPLING
12: UPDATING
13: DEFECTIVE
14: Error search mode
15: De-energised
253: Process image release in STOP
254: Watchdog
255: Not set
ZINFO2: Diagnostic address of the master
ZINFO3: DC state change
0: DC master out of sync
1: DC slave stations out of sync
0xEC80
EtherCAT: Bus error resolved
ZINFO1: Logical address of the IO system
ZINFO3 - Position 0: Station number
ZINFO3 - Position 11: IO system ID
ZINFO3 - Bit 15: System ID DP/PN
0xED10
EtherCAT: Breakdown bus
ZINFO1 - Position 0: New status
0: Undefined/Unkown
1: Init
2: PreOp
3: Bootstrap
4: SafeOp
8: Op
ZINFO1 - Position 8: Previous status
0: Undefined/Unkown
1: Init
2: PreOp
VIPA System SLIO
System specific event IDs
HB300 | CPU | 013-CCF0R00 | en | 19-30