5.6.4.2
Interrupt selection
Via
‘Basic parameters’
you can reach
‘Select interrupt’
. Here you can define the inter-
rupts the CPU will trigger. The following parameters are supported:
n
None: The interrupt function is disabled.
n
Process: The following events of the counter can trigger a hardware interrupt (select-
able via
‘Count’
):
–
Hardware gate opening
–
Hardware gate closing
–
On reaching the comparator
–
on Counting pulse
–
on overflow
–
on underflow
n
Diagprocess: A diagnostics interrupt is only triggered when a hardware inter-
rupt was lost.
5.6.4.3
Counter
Default values and structure of this dialog box depend on the selected
‘Operating mode’
.
Please consider that the range of values could be limited due to the used
projecting tool. With the VIPA SPEED7 Studio there are no limitations.
Chap. 12 ‘Configuration with VIPA SPEED7 Studio’ page 267
Parameter hardware con-
figuration
VIPA System SLIO
Deployment I/O periphery
Counting > Parametrization
HB300 | CPU | 013-CCF0R00 | en | 19-30