4-61
GB
EMU04041
CHECKING BATTERY
(for Electric start models)
WARNING
@
Battery electrolytic fluid is dangerous; it
contains sulfuric acid and therefore is
poisonous and highly caustic.
Always follow these preventive mea-
sures:
●
Avoid bodily contact with electrolytic
fluid as it can cause severe burns or
permanent eye injury.
●
Wear protective eye gear when han-
dling or working near batteries.
Antidote (EXTERNAL):
●
SKIN - Flush with water.
●
EYES - Flush with water for 15 minutes
and get immediate medical attention.
Antidote (INTERNAL):
●
Drink large quantities of water or milk
followed by milk of magnesia, beaten
egg, or vegetable oil. Get immediate
medical attention.
Batteries also generate explosive hydro-
gen gas; therefore, you should always
follow these preventive measures:
●
Charge batteries in a well-ventilated
area.
●
Keep batteries away from fire, sparks,
or open flames (e.g., welding equip-
ment, lighted cigarettes, etc.).
●
DO NOT SMOKE when charging or
handling batteries.
●
KEEP BATTERIES AND ELECTRO-
LYTIC FLUID OUT OF REACH OF CHIL-
DREN.
@
CAUTION:
@
●
A poorly maintained battery will
quickly deteriorate.
●
Ordinary tap-water contains minerals
harmful to a battery, and should not be
used for topping-up.
@
U68T73A0.book Page 61 Sunday, March 30, 2003 6:34 PM
Summary of Contents for F6A
Page 2: ...A5 shiro_tate fm Page 1 Monday May 28 2001 12 03 PM ...
Page 165: ...4 28 MEMO U68T73A0 book Page 28 Sunday March 30 2003 6 34 PM ...
Page 167: ...4 30 MEMO U68T73A0 book Page 30 Sunday March 30 2003 6 34 PM ...
Page 236: ...GB EMU00450 Chapter 6 INDEX INDEX 6 1 U68T73A0 book Page 1 Sunday March 30 2003 6 34 PM ...