General Procedures and Information
•
B/W - 4.6 sec. max (DC 2240/1632); 8.2 sec (DC 3535)
First Print Output Time (does not include ESS process time for prints); 8.5” x 11” (A4); Tray 1;
•
Color - 11.8 sec. max (DC 2240/1632); 9.0 sec (DC 3535)
•
B/W - 4.1 sec. max (DC 2240/1632); 5.0 sec (DC 3535)
Voltage Requirements
•
Single phase (two wires plus ground)
•
110 - 127 VAC/60 Hz (99 - 135 VAC, 55 to 62 Hz)
•
220 - 240 VAC/50 Hz (198 to 255 VAC, 48.5 to 51.5 Hz)
Power Consumption (5 minute average)
•
Machine Running: 1.584 kVA - NASG; 2.20 kVA ESG max.
•
Low Power: 204 watts max.
•
Sleep Mode: 80 watts max.
Warm up time: 66 sec. max.
Environmental Data and Requirements
Ambient Temperature and Humidity requirement:
•
Minimum: 10º C/50ºF at 15% humidity
•
Maximum: 35º C/99ºF at 85% humidity
IIT/DADF Specifications
Table 8 DADF Specifications
Document Size: Platen
Max size: 334 x 452 mm
Max scannable area: 297 x 432 mm
Document Size: DADF
5.5” x 8.5” (A5) LEF to 11” x 17” SEF (A3)
Max: 297 x 432 mm
Min: 148.5 x 210 mm
Document Weight: DADF
Min: 50 gsm/16lb
Max: 128 gsm/32lb (110 gsm in Duplex mode)
Document Capacity: DADF
50 sheets 100 gsm or less
40 sheets 101 to 128 gsm
R/E Capability:
Variable Percentages: 25% to 400% in 1% increments
Preset Percentages:
•
25%
•
50% (A3 to A5)
•
64% (11 x17 in. to 8.5 x 11 in.)
•
70% (A3 to A4; B4 to B5)
•
100%
•
129% (8.5 x 11 in. to 11 x17 in.)
•
141% (A4 to A3; B5 to B4)
•
400%
Presets can be changed in Tools mode
Summary of Contents for DocuColor 2240
Page 3: ...09 03 2 DC 3535 2240 1632 WC M24 Initial issue Introduction...
Page 8: ...09 03 vii DC 3535 2240 1632 WC M24 Introduction Initial issue Translated Warnings...
Page 23: ...09 03 xxii DC 3535 2240 1632 WC M24 Initial issue Introduction...
Page 25: ...09 03 1 2 DC 3535 2240 1632 WC M24 Initial issue Service Call Procedures...
Page 45: ...09 03 2 12 DC 3535 2240 1632 WC M24 Initial issue Status Indicator RAPs...
Page 51: ...09 03 2 18 DC 3535 2240 1632 WC M24 1 306 Initial issue Status Indicator RAPs...
Page 91: ...09 03 2 58 DC 3535 2240 1632 WC M24 3 986 Initial issue Status Indicator RAPs...
Page 113: ...09 03 2 80 DC 3535 2240 1632 WC M24 4 908 Initial issue Status Indicator RAPs...
Page 147: ...09 03 2 114 DC 3535 2240 1632 WC M24 6 391 Initial issue Status Indicator RAPs...
Page 189: ...09 03 2 156 DC 3535 2240 1632 WC M24 7 960 7 969 Initial issue Status Indicator RAPs...
Page 209: ...09 03 2 176 DC 3535 2240 1632 WC M24 8 631 8 900 Initial issue Status Indicator RAPs...
Page 251: ...09 03 2 218 DC 3535 2240 1632 WC M24 9 932 9 933 Initial issue Status Indicator RAPs...
Page 357: ...09 03 2 324 DC 3535 2240 1632 WC M24 15 790 Initial issue Status Indicator RAPs...
Page 417: ...09 03 2 384 DC 3535 2240 1632 WC M24 16 981 16 982 Initial issue Status Indicator RAPs...
Page 495: ...09 03 2 462 DC 3535 2240 1632 WC M24 20 798 20 799 Initial issue Status Indicator RAPs...
Page 497: ...09 03 2 464 DC 3535 2240 1632 WC M24 021 360 Initial issue Status Indicator RAPs...
Page 721: ...09 03 2 688 DC 3535 2240 1632 WC M24 116 900 Initial issue Status Indicator RAPs...
Page 727: ...09 03 2 694 DC 3535 2240 1632 WC M24 121 350 Initial issue Status Indicator RAPs...
Page 729: ...09 03 2 696 DC 3535 2240 1632 WC M24 202 399 Initial issue Status Indicator RAPs...
Page 745: ...09 03 3 2 DC 3535 2240 1632 WC M24 Initial issue Image Quality...
Page 783: ...09 03 3 40 DC 3535 2240 1632 WC M24 IBT Cleaner Streak Initial issue Image Quality...
Page 805: ...09 03 4 22 DC 3535 2240 1632 WC M24 REP 4 4 Initial issue Repairs and Adjustments...
Page 947: ...09 03 4 164 DC 3535 2240 1632 WC M24 ADJ 6 1 Initial issue Repairs and Adjustments...
Page 971: ...09 03 4 188 DC 3535 2240 1632 WC M24 ADJ 9 15 Initial issue Repairs and Adjustments...
Page 973: ...09 03 4 190 DC 3535 2240 1632 WC M24 ADJ 12 1 Initial issue Repairs and Adjustments...
Page 1093: ...09 03 6 2 DC 3535 2240 1632 WC M24 Initial issue General Procedures and Information...
Page 1239: ...09 03 7 2 DC 3535 2240 1632 WC M24 Initial issue Wiring Data...
Page 1283: ...09 03 7 46 DC 3535 2240 1632 WC M24 Plug Jack Locations Initial issue Wiring Data...
Page 1285: ...09 03 7 48 DC 3535 2240 1632 WC M24 AC Wirenets Initial issue Wiring Data Figure 2 ACN Wirenet...
Page 1477: ...09 03 9 2 DC 3535 2240 1632 WC M24 Initial issue Installation...
Page 1489: ...09 03 9 14 DC 3535 2240 1632 WC M24 Fax Kit Installation Initial issue Installation...