09/03
2-207
DC 3535/2240/1632, WC M24
9-684
Status Indicator RAPs
Initial issue
9-684 ADC Shutter
The machine logic detected an ADC Shutter operation failure.
Procedure
The machine is a DC3535.
Y
N
Enter
dC330
[009-078] and press
Start
.
The ADC Shutter Solenoid energized.
Y
N
There is +24VDC from
P/J536
-A7 on the I/F PWB to GND.
Y
N
Go to
Figure 1
. Check the wires and connectors. If the check is OK, replace the
I/F PWB (
PL 9.1
). If the problem continues, replace the ADC Sensor (
PL 1.3
).
Enter
dC330
[009-078] and press
Start
.
There is 0VDC from
P/J536
-A8 on the I/F
PWB (
PL 9.1
) to GND.
Y
N
Check the wires and connectors. If the check is OK, replace the I/F PWB (
PL
9.1
). If the problem continues, replace the MCU PWB (
PL 13.1
). If the problem
continues, replace the ADC Sensor (
PL 1.3
).
Enter
dC330
[009-079] and press
Start
.
The voltage from
P/J536
-A6 on the I/F
PWB to GND changed to 0VDC momentarily.
Y
N
Go to
Figure 1
. Check the wires and connectors. If the check is OK, replace the
I/F PWB (
PL 9.1
). If the problem continues, replace the MCU PWB (
PL 13.1
). If
the problem continues, replace the ADC Sensor (
PL 1.3
).
Go to
Figure 1
. Check the wires and connectors. If the check is OK, replace the ADC
Sensor (
PL 1.3
).
After checking that no failures are detected during normal operation, go to call closeout.
Enter
dC330
[009-078] and press
Start
.
The ADC Shutter Solenoid energized.
Y
N
There is +24VDC from
P/J536
-A5 on the I/F PWB (
PL 9.1
) to GND.
Y
N
Go to
Figure 2
. Check the wires and connectors. If the check is OK, replace the I/F
PWB (
PL 9.1
). If the problem continues, replace the ADC Sensor (
PL 1.3
).
Enter
dC330
[009-078] and press
Start
.
There is 0VDC from
P/J536
-A6 on the I/F
PWB to GND.
Y
N
Check the wires and connectors. If the check is OK, replace the I/F PWB (
PL 9.1
)If
the problem continues, replace the MCU PWB (
PL 13.1
). If the problem continues,
replace the ADC Sensor (
PL 1.3
).
Enter
dC330
[009-079] and press
Start
.
The voltage from
P/J536
-A4 on the I/F PWB
to GND changed to 0VDC momentarily.
Y
N
Go to
Figure 2
. Check the wires and connectors. If the check is OK, replace the I/F
PWB (
PL 9.1
). If the problem continues, replace the MCU PWB (
PL 13.1
). If the
problem continues, replace the ADC Sensor (
PL 1.3
).
Go to
Figure 2
. Check the wires and connectors. If the check is OK, replace the ADC Sen-
sor (
PL 1.3
).
After checking that no failures are detected during normal operation, go to call closeout.
A
A
Summary of Contents for DocuColor 2240
Page 3: ...09 03 2 DC 3535 2240 1632 WC M24 Initial issue Introduction...
Page 8: ...09 03 vii DC 3535 2240 1632 WC M24 Introduction Initial issue Translated Warnings...
Page 23: ...09 03 xxii DC 3535 2240 1632 WC M24 Initial issue Introduction...
Page 25: ...09 03 1 2 DC 3535 2240 1632 WC M24 Initial issue Service Call Procedures...
Page 45: ...09 03 2 12 DC 3535 2240 1632 WC M24 Initial issue Status Indicator RAPs...
Page 51: ...09 03 2 18 DC 3535 2240 1632 WC M24 1 306 Initial issue Status Indicator RAPs...
Page 91: ...09 03 2 58 DC 3535 2240 1632 WC M24 3 986 Initial issue Status Indicator RAPs...
Page 113: ...09 03 2 80 DC 3535 2240 1632 WC M24 4 908 Initial issue Status Indicator RAPs...
Page 147: ...09 03 2 114 DC 3535 2240 1632 WC M24 6 391 Initial issue Status Indicator RAPs...
Page 189: ...09 03 2 156 DC 3535 2240 1632 WC M24 7 960 7 969 Initial issue Status Indicator RAPs...
Page 209: ...09 03 2 176 DC 3535 2240 1632 WC M24 8 631 8 900 Initial issue Status Indicator RAPs...
Page 251: ...09 03 2 218 DC 3535 2240 1632 WC M24 9 932 9 933 Initial issue Status Indicator RAPs...
Page 357: ...09 03 2 324 DC 3535 2240 1632 WC M24 15 790 Initial issue Status Indicator RAPs...
Page 417: ...09 03 2 384 DC 3535 2240 1632 WC M24 16 981 16 982 Initial issue Status Indicator RAPs...
Page 495: ...09 03 2 462 DC 3535 2240 1632 WC M24 20 798 20 799 Initial issue Status Indicator RAPs...
Page 497: ...09 03 2 464 DC 3535 2240 1632 WC M24 021 360 Initial issue Status Indicator RAPs...
Page 721: ...09 03 2 688 DC 3535 2240 1632 WC M24 116 900 Initial issue Status Indicator RAPs...
Page 727: ...09 03 2 694 DC 3535 2240 1632 WC M24 121 350 Initial issue Status Indicator RAPs...
Page 729: ...09 03 2 696 DC 3535 2240 1632 WC M24 202 399 Initial issue Status Indicator RAPs...
Page 745: ...09 03 3 2 DC 3535 2240 1632 WC M24 Initial issue Image Quality...
Page 783: ...09 03 3 40 DC 3535 2240 1632 WC M24 IBT Cleaner Streak Initial issue Image Quality...
Page 805: ...09 03 4 22 DC 3535 2240 1632 WC M24 REP 4 4 Initial issue Repairs and Adjustments...
Page 947: ...09 03 4 164 DC 3535 2240 1632 WC M24 ADJ 6 1 Initial issue Repairs and Adjustments...
Page 971: ...09 03 4 188 DC 3535 2240 1632 WC M24 ADJ 9 15 Initial issue Repairs and Adjustments...
Page 973: ...09 03 4 190 DC 3535 2240 1632 WC M24 ADJ 12 1 Initial issue Repairs and Adjustments...
Page 1093: ...09 03 6 2 DC 3535 2240 1632 WC M24 Initial issue General Procedures and Information...
Page 1239: ...09 03 7 2 DC 3535 2240 1632 WC M24 Initial issue Wiring Data...
Page 1283: ...09 03 7 46 DC 3535 2240 1632 WC M24 Plug Jack Locations Initial issue Wiring Data...
Page 1285: ...09 03 7 48 DC 3535 2240 1632 WC M24 AC Wirenets Initial issue Wiring Data Figure 2 ACN Wirenet...
Page 1477: ...09 03 9 2 DC 3535 2240 1632 WC M24 Initial issue Installation...
Page 1489: ...09 03 9 14 DC 3535 2240 1632 WC M24 Fax Kit Installation Initial issue Installation...