09/03
6-7
DC 3535/2240/1632, WC M24
dC118, dC120
General Procedures and Information
Initial issue
dC118 Jam Counter
Purpose
Displays the number of occurrences of Jams from time of previous Complete Closeout on ser-
vice exit until present.
NOTE: This procedure does not count jams detected while in the Service Mode.
Procedure
1.
Enter the
Diagnostic Mode
. Refer to
Entering Diagnostic Mode using the PWS
.
2.
Select
Maintenance
on the Service Entry Screen.
3.
Select the
Jam Counters (dC 118)
.
4.
The screen displays all jam-related fault codes, and the number of times that the fault has
occurred since the last time the
Complete Closeout
option was selected when exiting
Diagnostic Mode.
5.
The following subsets of data are selectable:
•
All Jams
- This is the default. All jam-related faults are listed
•
DADF Jams
- Selecting this tab lists only the DADF jam codes.
•
Paper Jams
- Selecting this tab lists only the paper supply and paper feeding jam codes.
•
Non-Zero Jams
- Selecting this tab lists only those jam codes that have had at least one occurrence
since the last time the
Complete Closeout
option was selected.
dC120 Fault Counter
Purpose
Displays the number of occurrences of each fault since the last Service Exit with the Complete
Closeout option selected.
NOTE:
•
The machine does not count the faults detected while in the Service Mode.
•
The machine does not count interlock open detected faults while the Main Processor is
stopped.
Procedure
1.
Enter the
Diagnostic Mode
. Refer to
Entering Diagnostic Mode using the PWS
.
2.
Select
Maintenance
on the Service Entry Screen.
3.
Select the
Fail Counters (dC120)
tab.
4.
The screen displays all fault codes that have occurred since the last time the
Complete
Closeout
option was selected when exiting Diagnostic Mode.
The codes are listed in ascending order; to list in descending order, click on
ID
in the table
header.
If machine data was previously saved to diskette, and Diagnostic Mode was entered with
the
Read From Diskettes
option selected, the previous fault history #Occurrence will dis-
play in the P1 column. If this same procedure was performed previously, the fault history
#Occurrence will display in P2, then P3, up to columns P7.
5.
The following subsets of data are selectable:
•
All Faults
•
DADF Faults
•
System faults
•
Xero Faults
Summary of Contents for DocuColor 2240
Page 3: ...09 03 2 DC 3535 2240 1632 WC M24 Initial issue Introduction...
Page 8: ...09 03 vii DC 3535 2240 1632 WC M24 Introduction Initial issue Translated Warnings...
Page 23: ...09 03 xxii DC 3535 2240 1632 WC M24 Initial issue Introduction...
Page 25: ...09 03 1 2 DC 3535 2240 1632 WC M24 Initial issue Service Call Procedures...
Page 45: ...09 03 2 12 DC 3535 2240 1632 WC M24 Initial issue Status Indicator RAPs...
Page 51: ...09 03 2 18 DC 3535 2240 1632 WC M24 1 306 Initial issue Status Indicator RAPs...
Page 91: ...09 03 2 58 DC 3535 2240 1632 WC M24 3 986 Initial issue Status Indicator RAPs...
Page 113: ...09 03 2 80 DC 3535 2240 1632 WC M24 4 908 Initial issue Status Indicator RAPs...
Page 147: ...09 03 2 114 DC 3535 2240 1632 WC M24 6 391 Initial issue Status Indicator RAPs...
Page 189: ...09 03 2 156 DC 3535 2240 1632 WC M24 7 960 7 969 Initial issue Status Indicator RAPs...
Page 209: ...09 03 2 176 DC 3535 2240 1632 WC M24 8 631 8 900 Initial issue Status Indicator RAPs...
Page 251: ...09 03 2 218 DC 3535 2240 1632 WC M24 9 932 9 933 Initial issue Status Indicator RAPs...
Page 357: ...09 03 2 324 DC 3535 2240 1632 WC M24 15 790 Initial issue Status Indicator RAPs...
Page 417: ...09 03 2 384 DC 3535 2240 1632 WC M24 16 981 16 982 Initial issue Status Indicator RAPs...
Page 495: ...09 03 2 462 DC 3535 2240 1632 WC M24 20 798 20 799 Initial issue Status Indicator RAPs...
Page 497: ...09 03 2 464 DC 3535 2240 1632 WC M24 021 360 Initial issue Status Indicator RAPs...
Page 721: ...09 03 2 688 DC 3535 2240 1632 WC M24 116 900 Initial issue Status Indicator RAPs...
Page 727: ...09 03 2 694 DC 3535 2240 1632 WC M24 121 350 Initial issue Status Indicator RAPs...
Page 729: ...09 03 2 696 DC 3535 2240 1632 WC M24 202 399 Initial issue Status Indicator RAPs...
Page 745: ...09 03 3 2 DC 3535 2240 1632 WC M24 Initial issue Image Quality...
Page 783: ...09 03 3 40 DC 3535 2240 1632 WC M24 IBT Cleaner Streak Initial issue Image Quality...
Page 805: ...09 03 4 22 DC 3535 2240 1632 WC M24 REP 4 4 Initial issue Repairs and Adjustments...
Page 947: ...09 03 4 164 DC 3535 2240 1632 WC M24 ADJ 6 1 Initial issue Repairs and Adjustments...
Page 971: ...09 03 4 188 DC 3535 2240 1632 WC M24 ADJ 9 15 Initial issue Repairs and Adjustments...
Page 973: ...09 03 4 190 DC 3535 2240 1632 WC M24 ADJ 12 1 Initial issue Repairs and Adjustments...
Page 1093: ...09 03 6 2 DC 3535 2240 1632 WC M24 Initial issue General Procedures and Information...
Page 1239: ...09 03 7 2 DC 3535 2240 1632 WC M24 Initial issue Wiring Data...
Page 1283: ...09 03 7 46 DC 3535 2240 1632 WC M24 Plug Jack Locations Initial issue Wiring Data...
Page 1285: ...09 03 7 48 DC 3535 2240 1632 WC M24 AC Wirenets Initial issue Wiring Data Figure 2 ACN Wirenet...
Page 1477: ...09 03 9 2 DC 3535 2240 1632 WC M24 Initial issue Installation...
Page 1489: ...09 03 9 14 DC 3535 2240 1632 WC M24 Fax Kit Installation Initial issue Installation...