09/03
3-19
DC 3535/2240/1632, WC M24
IQ16, IQ17
Image Quality
Initial issue
IQ16 Spots RAP
Initial Actions
Ensure that the paper in use is fresh, dry, and within specification for weight and quality.
Check print driver and copier control panel settings to ensure the media is being run in the
proper mode.
Compare the spots against the samples in the Image Quality Defects supplement. If the defect
matches the Debris Centered Deletions sample, go to the
IQ9
RAP.
Procedure
The defect occurs in Copy mode only.
Y
N
The spots occur at a fixed interval on each print.
Y
N
NOTE: The repetition rate for Transfer Belt defects varies considerably, depending
on paper size and mode of operation. The defect may appear as frequently as every
3rd sheet, or may only occur every 14 sheets.
The defect occurs in approximately the same position IB to OB on multiple
prints.
Y
N
The problem is Fuser offset and/or lead edge smears or spots.
Y
N
CAUTION
Do not use a vacuum cleaner or any solvents in the following step. Dam-
age to the IBT Cleaner Assembly will result.
Do not attempt to clean the cleaning blade. It WILL be damaged if any
wiping or excessive pressure is applied.
Remove the IBT Cleaner Assembly (
REP 9.16
). Carefully clean the clean-
ing blade and the Mylar shield with a soft brush or a lint free cloth. Brush
away any accumulation of toner on the foam seal and the outside sur-
faces. Wipe the surface of the Transfer Belt with a lint free cloth.
If the problem continues, replace the IBT Cleaner Assembly (
PL 5.3
).
Go to the
IQ13
RAP.
Check the Transfer Belt (
PL 5.3
) for dirt or damage. Clean or replace as required.
Go to the
IQ14
RAP.
Ensure that the original is free from the defect.
Clean the Platen Glass and Lens.
IQ17 Missing Colors RAP
One or more of the primary (YMCK) colors is missing from the image.
Initial Actions
Determine if the problem is in copy or print mode.
If the problem occurs in print mode only, check the troubleshooting portion of the Network Con-
troller Service Documentation.
If the problem is in copy mode and print mode, or if the problem persists continue the RAP.
Procedure
Enter
dC612
. Make a print of Test Pattern 22 to determine which colors are missing. Make a
print of Test Pattern 2 (Halftone IOT) 50% for the missing colors.
Color is still missing.
Y
N
Replace the IIT/IPS PWB (
PL 18.3
).
Go to
IQ21
Developer Bias RAP and check the Developer Bias circuit. If the circuits are OK,
check the ROS for damage or contamination. Clean, repair or replace as required (
PL 3.1
).
Summary of Contents for DocuColor 2240
Page 3: ...09 03 2 DC 3535 2240 1632 WC M24 Initial issue Introduction...
Page 8: ...09 03 vii DC 3535 2240 1632 WC M24 Introduction Initial issue Translated Warnings...
Page 23: ...09 03 xxii DC 3535 2240 1632 WC M24 Initial issue Introduction...
Page 25: ...09 03 1 2 DC 3535 2240 1632 WC M24 Initial issue Service Call Procedures...
Page 45: ...09 03 2 12 DC 3535 2240 1632 WC M24 Initial issue Status Indicator RAPs...
Page 51: ...09 03 2 18 DC 3535 2240 1632 WC M24 1 306 Initial issue Status Indicator RAPs...
Page 91: ...09 03 2 58 DC 3535 2240 1632 WC M24 3 986 Initial issue Status Indicator RAPs...
Page 113: ...09 03 2 80 DC 3535 2240 1632 WC M24 4 908 Initial issue Status Indicator RAPs...
Page 147: ...09 03 2 114 DC 3535 2240 1632 WC M24 6 391 Initial issue Status Indicator RAPs...
Page 189: ...09 03 2 156 DC 3535 2240 1632 WC M24 7 960 7 969 Initial issue Status Indicator RAPs...
Page 209: ...09 03 2 176 DC 3535 2240 1632 WC M24 8 631 8 900 Initial issue Status Indicator RAPs...
Page 251: ...09 03 2 218 DC 3535 2240 1632 WC M24 9 932 9 933 Initial issue Status Indicator RAPs...
Page 357: ...09 03 2 324 DC 3535 2240 1632 WC M24 15 790 Initial issue Status Indicator RAPs...
Page 417: ...09 03 2 384 DC 3535 2240 1632 WC M24 16 981 16 982 Initial issue Status Indicator RAPs...
Page 495: ...09 03 2 462 DC 3535 2240 1632 WC M24 20 798 20 799 Initial issue Status Indicator RAPs...
Page 497: ...09 03 2 464 DC 3535 2240 1632 WC M24 021 360 Initial issue Status Indicator RAPs...
Page 721: ...09 03 2 688 DC 3535 2240 1632 WC M24 116 900 Initial issue Status Indicator RAPs...
Page 727: ...09 03 2 694 DC 3535 2240 1632 WC M24 121 350 Initial issue Status Indicator RAPs...
Page 729: ...09 03 2 696 DC 3535 2240 1632 WC M24 202 399 Initial issue Status Indicator RAPs...
Page 745: ...09 03 3 2 DC 3535 2240 1632 WC M24 Initial issue Image Quality...
Page 783: ...09 03 3 40 DC 3535 2240 1632 WC M24 IBT Cleaner Streak Initial issue Image Quality...
Page 805: ...09 03 4 22 DC 3535 2240 1632 WC M24 REP 4 4 Initial issue Repairs and Adjustments...
Page 947: ...09 03 4 164 DC 3535 2240 1632 WC M24 ADJ 6 1 Initial issue Repairs and Adjustments...
Page 971: ...09 03 4 188 DC 3535 2240 1632 WC M24 ADJ 9 15 Initial issue Repairs and Adjustments...
Page 973: ...09 03 4 190 DC 3535 2240 1632 WC M24 ADJ 12 1 Initial issue Repairs and Adjustments...
Page 1093: ...09 03 6 2 DC 3535 2240 1632 WC M24 Initial issue General Procedures and Information...
Page 1239: ...09 03 7 2 DC 3535 2240 1632 WC M24 Initial issue Wiring Data...
Page 1283: ...09 03 7 46 DC 3535 2240 1632 WC M24 Plug Jack Locations Initial issue Wiring Data...
Page 1285: ...09 03 7 48 DC 3535 2240 1632 WC M24 AC Wirenets Initial issue Wiring Data Figure 2 ACN Wirenet...
Page 1477: ...09 03 9 2 DC 3535 2240 1632 WC M24 Initial issue Installation...
Page 1489: ...09 03 9 14 DC 3535 2240 1632 WC M24 Fax Kit Installation Initial issue Installation...