09/03
2-89
DC 3535/2240/1632, WC M24
5-195
Status Indicator RAPs
Initial issue
5-195 Document Size Mismatch
Different sized documents are detected in the NO MIX mode.
Initial Actions
This fault can be caused by the following:
•
Mixed size documents are fed without selecting that option on the UI.
•
There is too much curl in the documents being fed through the DADF.
•
The documents are improperly loaded.
•
The type of document being fed (coated paper, etc.)
Instruct the operator on proper DADF operation.
Procedure
Enter
dC330
[005-150] and select
Start
. Actuate the DADF Size Sensor 1 (Rear) (
PL 20.5
).
The display changes.
Y
N
The display indicates a constant High.
Y
N
Go to
Flag 1
. Check the wire for a short circuit to GND. If the wire is good, replace
the Size Sensor 1 (Rear) (
PL 20.5
).
Go to
Flag 1
and
Flag 2
. Check the wires for an open circuit. If the wires are good, replace
the Size Sensor 1 (Rear) (
PL 20.5
). If the problem continues, replace the DADF Control
PWB (
PL 20.3
).
Enter
dC330
[005-151] and press
Start
. Actuate DADF Size Sensor 2 (Front) (
PL 20.5
).
The
display changes.
Y
N
The display indicates a constant High.
Y
N
Go to
Flag 3
. Check the wire for a short circuit to GND. If the wire is good, replace
the Size Sensor 1 (Rear) (
PL 20.5
).
Go to
Flag 3
and
Flag 4
. Check the wires for an open circuit. If the wires are good, replace
the Size Sensor 2 (Front) (
PL 20.5
). If the problem continues, replace the DADF Control
PWB (PL 20.3).
Open the Document Feed Assembly and block the Registration Sensor with a sheet of paper.
The display changes.
Y
N
Go to the
5-702
Registration Sensor RAP
Check the following:
•
Size Sensor for correct installation (
REP 5.12
).
•
Multiple feed due to retard malfunction (
PL 20.5
).
•
DADF document skew caused by misadjustments (
ADJ 5.2
) (
ADJ 5.3
) (
ADJ 5.4
).
•
Document meets specification
•
Different document size (mixed documents)
Figure 1 5-195 RAP Circuit Diagram - Size Sensor 1 (Rear)
Figure 2 5-195 RAP Circuit Diagram - Size Sensor 2 (Front)
Figure 3 DADF Control PWB
Summary of Contents for DocuColor 2240
Page 3: ...09 03 2 DC 3535 2240 1632 WC M24 Initial issue Introduction...
Page 8: ...09 03 vii DC 3535 2240 1632 WC M24 Introduction Initial issue Translated Warnings...
Page 23: ...09 03 xxii DC 3535 2240 1632 WC M24 Initial issue Introduction...
Page 25: ...09 03 1 2 DC 3535 2240 1632 WC M24 Initial issue Service Call Procedures...
Page 45: ...09 03 2 12 DC 3535 2240 1632 WC M24 Initial issue Status Indicator RAPs...
Page 51: ...09 03 2 18 DC 3535 2240 1632 WC M24 1 306 Initial issue Status Indicator RAPs...
Page 91: ...09 03 2 58 DC 3535 2240 1632 WC M24 3 986 Initial issue Status Indicator RAPs...
Page 113: ...09 03 2 80 DC 3535 2240 1632 WC M24 4 908 Initial issue Status Indicator RAPs...
Page 147: ...09 03 2 114 DC 3535 2240 1632 WC M24 6 391 Initial issue Status Indicator RAPs...
Page 189: ...09 03 2 156 DC 3535 2240 1632 WC M24 7 960 7 969 Initial issue Status Indicator RAPs...
Page 209: ...09 03 2 176 DC 3535 2240 1632 WC M24 8 631 8 900 Initial issue Status Indicator RAPs...
Page 251: ...09 03 2 218 DC 3535 2240 1632 WC M24 9 932 9 933 Initial issue Status Indicator RAPs...
Page 357: ...09 03 2 324 DC 3535 2240 1632 WC M24 15 790 Initial issue Status Indicator RAPs...
Page 417: ...09 03 2 384 DC 3535 2240 1632 WC M24 16 981 16 982 Initial issue Status Indicator RAPs...
Page 495: ...09 03 2 462 DC 3535 2240 1632 WC M24 20 798 20 799 Initial issue Status Indicator RAPs...
Page 497: ...09 03 2 464 DC 3535 2240 1632 WC M24 021 360 Initial issue Status Indicator RAPs...
Page 721: ...09 03 2 688 DC 3535 2240 1632 WC M24 116 900 Initial issue Status Indicator RAPs...
Page 727: ...09 03 2 694 DC 3535 2240 1632 WC M24 121 350 Initial issue Status Indicator RAPs...
Page 729: ...09 03 2 696 DC 3535 2240 1632 WC M24 202 399 Initial issue Status Indicator RAPs...
Page 745: ...09 03 3 2 DC 3535 2240 1632 WC M24 Initial issue Image Quality...
Page 783: ...09 03 3 40 DC 3535 2240 1632 WC M24 IBT Cleaner Streak Initial issue Image Quality...
Page 805: ...09 03 4 22 DC 3535 2240 1632 WC M24 REP 4 4 Initial issue Repairs and Adjustments...
Page 947: ...09 03 4 164 DC 3535 2240 1632 WC M24 ADJ 6 1 Initial issue Repairs and Adjustments...
Page 971: ...09 03 4 188 DC 3535 2240 1632 WC M24 ADJ 9 15 Initial issue Repairs and Adjustments...
Page 973: ...09 03 4 190 DC 3535 2240 1632 WC M24 ADJ 12 1 Initial issue Repairs and Adjustments...
Page 1093: ...09 03 6 2 DC 3535 2240 1632 WC M24 Initial issue General Procedures and Information...
Page 1239: ...09 03 7 2 DC 3535 2240 1632 WC M24 Initial issue Wiring Data...
Page 1283: ...09 03 7 46 DC 3535 2240 1632 WC M24 Plug Jack Locations Initial issue Wiring Data...
Page 1285: ...09 03 7 48 DC 3535 2240 1632 WC M24 AC Wirenets Initial issue Wiring Data Figure 2 ACN Wirenet...
Page 1477: ...09 03 9 2 DC 3535 2240 1632 WC M24 Initial issue Installation...
Page 1489: ...09 03 9 14 DC 3535 2240 1632 WC M24 Fax Kit Installation Initial issue Installation...