![Winbond W83627DHG Manual Download Page 56](http://html1.mh-extra.com/html/winbond/w83627dhg/w83627dhg_manual_984492056.webp)
W83627DHG
Publication Release Date: Aug, 22, 2007
-44- Version
1.4
160
170
150
Fan
output
100
0
50
A
C
Count
(%)
The following tables show current temperatures, fan output values and the relative control registers at
Thermal Cruise
TM
and Fan Speed Cruise
TM
mode.
Display Registers - at S
MART
F
AN
TM
I Mode
DESCRIPTION
REGISTER
ADDRESS
REGISTER NAME
ATTRIBUTE
BIT DATA
Current CPU
Temperature
Bank1 Index
50h ,51h
CPUTIN Temperature
Sensor
Read only
8 MSB, 1°C bit 7,
0.5 °C
Current SYS
Temperature
Bank 0 Index
27h
SYSTIN Temperature
Sensor
Read only
8 MSB, 1°C
Current AUX
Temperature
Bank2 Index
50h,51h
AUXTIN Temperature
Sensor
Read only
8 MSB, 1°C bit 7,
0.5 °C
Current
CPUFANOUT0
Output Value
Bank0 Index
03h
CPUFANOUT0 Output
Value Select
80h / FFh by
strapping
bits 7~0
CPUFANOUT0
Value
Current
SYSFANOUT
Output Value
Bank0 Index
01h
SYSFANOUT Output
Value Select
FFh
bits 7~0
SYSFANOUT Value
Current
AUXFANOUT
Output Value
Bank0 Index
11h
AUXFANOUT Output
Value Select
FFh
bits 7~0
AUXFANOUT Value
Current
CPUFANOUT1
Output Value
Bank0 Index
61h
CPUFANOUT1 Output
Value Select
80h / FFh by
strapping
bits 7~0
CPUFANOUT1
Value