KBC Timing Parameters, continued
SYMBOL DESCRIPTION MIN.
MAX.
UNIT
T22
Duration of CLK inactive
30
50
μ
S
T23
Duration of CLK active
30
50
μ
S
T24
Time from inactive CLK transition, used to time when
the auxiliary device sample DATA
5 25
μ
S
T25
Time of inhibit mode
100
300
μ
S
T26
Time from rising edge of CLK to DATA transition
5
T28-5
μ
S
T27
Duration of CLK inactive
30
50
μ
S
T28
Duration of CLK active
30
50
μ
S
T29
Time from DATA transition to falling edge of CLK
5
25
μ
S