![Winbond W83627DHG Manual Download Page 119](http://html1.mh-extra.com/html/winbond/w83627dhg/w83627dhg_manual_984492119.webp)
W83627DHG
Publication Release Date: Aug, 22, 2007
-107- Version
1.4
Bit 2: Smart Fan of AUXFANIN warning status.
1: Selected temperature has been over the target temperature for three minutes at full fan speed
in Thermal Cruise
TM
mode.
0: Selected temperature has not reached the warning range.
Bit 1: VBAT Voltage status.
1: VBAT voltage is over or under the allowed range.
0: VBAT voltage is in the allowed range.
Bit 0: 3VSB Voltage status.
1: 3VSB voltage is over or under the allowed range.
0: 3VSB voltage is in the allowed range.
8.95 Reserved Register - Index 5Ch ~ 5Fh (Bank 4)
8.96 Value RAM 2
⎯
Index 50h-59h (Bank 5)
ADDRESS A6-A0
DESCRIPTION
50h
3VSB reading
51h
VBAT reading. The reading is meaningless unless EN_VBAT_MN (Bank0
Index 5Dh, bit0) is set.
52h Reserved
53h
AUXFANIN1 reading
Note: This location stores the number of counts of the internal clock per
revolution.
54h
3VSB High Limit
55h
3VSB Low Limit
56h
VBAT High Limit
57h
VBAT Low Limit
58h Reserved
59h Reserved
5Ah Reserved
5Bh Reserved
5Ch
AUXFANIN1 Fan Count Limit
Note:
It is the number of counts of the internal clock for the Low Limit of
the fan speed.
8.97 Reserved Register - Index 50h ~ 57h (Bank 6)