Logical Device A, CR E6h
4
R / W
Power loss Last State Flag.
(VBAT)
0: ON
1: OFF
21.3.2 VSBGATE# Timing – for UBE and UBF Version Only
S0
S0
S3
SUSC#
SUSB#
PSON#
3VCC
VSBGATE#
t3
t4
t1
t2
VSBGATE# drives low only
when SUSB# is active and
Logical Device A, CR[E4h] bit
4 is set to
“
1
"
VSBGATE# is reset to high
after PSON# is active
SYMBOL PARAMETER
MIN
MAX
UNIT
t1
SUSB# active to VSBGATE# active
0
80
nS
t2
PSON# active to VSBGATE# inactive
90
142
mS
t3
SUSB# inactive to PSON# active
0
80
nS
t4
SUSB# active to PSON# inactive
28
39
mS