21.3.10.5. EPP Data or Address Write Cycle Timing Parameters
PARAMETER SYM.
MIN.
MAX.
UNIT
PBDIR Low to
WRITE
Asserted
t10 0 nS
WAIT
Asserted to
WRITE
Asserted
t11 60 185 nS
WAIT
Asserted to
WRITE
Change
t12 60 185 nS
WAIT
Asserted to PD Invalid
t14 0 nS
PD Invalid to Command Asserted
t15
10
nS
WAIT
Asserted to Command Asserted
t17 60 210 nS
WAIT
Deasserted to Command Deasserted
t18 60 190 nS
Command Asserted to
WAIT
Deasserted
t19 0 10
μ
S
Time out
t20
10
12
μ
S
Command Deasserted to
WAIT
Asserted
t21 0 nS
Ax Valid to
IOW
Asserted
t1 40 nS
SD Valid to Asserted
t2
10
nS
IOW
Deasserted to Ax Invalid
t3 10 nS
WAIT
Deasserted to IOCHRDY Deasserted
t4 0 nS
Command Asserted to
WAIT
Deasserted
t5 10 nS
IOW
Deasserted to
IOW
or
IOR
Asserted
t6 40 nS
IOCHRDY Deasserted to
IOW
Deasserted
t7 0 24 nS
WAIT
Asserted to Command Asserted
t8 60
160 nS
IOW
Asserted to
WAIT
Asserted
t9 0 70 nS
PBDIR Low to
WRITE
Asserted
t10 0 nS
WAIT
Asserted to
WRITE
Asserted
t11 60 185 nS
WAIT
Asserted to
WRITE
Change
t12 60 185 nS
IOW
Asserted to PD Valid
t13 0 50 nS
WAIT
Asserted to PD Invalid
t14 0 nS
PD Invalid to Command Asserted
t15
10
nS
IOW
to Command Asserted
t16 5 35 nS
WAIT
Asserted to Command Asserted
t17 60 210 nS
WAIT
Deasserted to Command Deasserted
t18 60 190 nS
Command Asserted to
WAIT
Deasserted
t19 0 10
μ
S
Summary of Contents for W83627DHG