![Winbond W83627DHG Manual Download Page 53](http://html1.mh-extra.com/html/winbond/w83627dhg/w83627dhg_manual_984492053.webp)
W83627DHG
Publication Release Date: Aug, 22, 2007
-41- Version
1.4
7.6.3 S
MART
F
AN
TM
Control
The W83627DHG supports two S
MART
F
AN
TM
I features—Thermal Cruise
TM
mode and Fan Speed
Cruise
TM
mode—and S
MART
F
AN
TM
III. Each of these is discussed in the following sections. When
enabling S
MART
F
AN
TM
I features, fan output starts from the previous setting in Bank0 Index 01h, Index
03h, Index 11h and Index 61h
There are four pairs of temperature sensors and fan outputs in S
MART
F
AN
TM
I, it is illustrated in the
figure below.
7.6.3.1. Thermal
Cruise
TM
Mode
Four pairs of temperature sensors and fan outputs in Thermal Cruise
TM
mode:
•
SYSTIN and SYSFANOUT
•
CPUFANOUT0 and the temperature sensor selected by Bank0 Index 49h, bits 2 ~ 0
•
AUXFANOUT and the temperature sensor selected by Bank0 Index 49h, bits 6 ~ 4
•
CPUFANOUT1 and the temperature sensor selected by Bank0 Index 4Ah, bits 7 ~ 5
Pin 115
CPUFANOUT0
Pin 116
SYSFANOUT
CPUTIN
PECI_Agent1
PECI_Agent2
PECI_Agent3
PECI_Agent4
SYSTIN
AUXTIN
PECI_Agent1
PECI_Agent2
PECI_Agent3
PECI_Agent4
Pin 120
CPUFANOUT1
Pin 7
AUXFANOUT
SYSTIN
CPUTIN
AUXTIN
PECI_Agent1
PECI_Agent2
PECI_Agent3
PECI_Agent4
Summary of Contents for W83627DHG