Once the far-end unit has been looped back, start the test by pressing the
Start
button. When the all of the selected test are
completed, the BERT test suite will stop automatically. Once all tests have been completed and there is no need to test again, go
back to the Control tab, and press the
Loop Down
button. This will send a loop down command to the far-end unit to remove
the loopback that is in place.
15.2.2 BERT Results
15.2.2.1 Summary
Summary tab:
The following results including the Start (ST) and Elapsed (ET) times are displayed:
Line Rate
(Mbps)
:
Negotiated rate of the interface (10M, 100M, or 1000M). This value is always fixed since it depends on
the maximum capacity of the link under test, hence the test interface that is configured.
Framed Rate:
(P MAC/IP VLAN Tag + Type/ CRC) / (P Total Overhead) * Line Rate
% (in Mbps).
Data Rate:
Payload / (P Total Overhead) * Line Rate %.
Utilization:
% of Line Rate. For example, if we transmit 100Mbps on a 1Gbps interface then the utilization value is 10%
(or 100Mbps) of the total link capacity (or Line Rate).
Number of bytes
Pause Frames:
Total number of transmitted and received ethernet pause flow-control frames.
BERT Results - Summary
15.2.2.2 Errors
Errors tab:
The following errors (Current and Total) are displayed:
Bits:
Indicates errors related to test pattern (Bit Error or LSS [Pattern Loss])
BER:
Bit Error Ratio
Symbol:
Declared when an invalid code-group in the transmission code is detected
FCS/CRC:
Number of received frames with an invalid FCS
IP Checksum
(Layer 3 only)
Jabber frames:
Number of received frames larger than 1518 bytes containing an invalid FCS
Runt frames:
Number of received frames smaller than 64 bytes containing an invalid FCS
BERT Results - Errors
TX300S_e-manual_D07-00-064P_RevA00
Summary of Contents for VePAL TX300M
Page 1: ...TX300S_e manual_D07 00 064P_RevA00...
Page 12: ...23 0 About VeEX Go back to top TX300S_e manual_D07 00 064P_RevA00...
Page 29: ...Go back to top Go back to TOC TX300S_e manual_D07 00 064P_RevA00...
Page 47: ...Go back to top Go back to TOC TX300S_e manual_D07 00 064P_RevA00...
Page 58: ...Go back to top Go back to TOC TX300S_e manual_D07 00 064P_RevA00...
Page 61: ...Tx Structure Setup Graphical Mode Tx Payload Setup TX300S_e manual_D07 00 064P_RevA00...
Page 71: ...Go back to top Go back to TOC TX300S_e manual_D07 00 064P_RevA00...
Page 92: ...TX300S_e manual_D07 00 064P_RevA00...
Page 126: ...TX300S_e manual_D07 00 064P_RevA00...
Page 182: ...Go back to top Go back to TOC TX300S_e manual_D07 00 064P_RevA00...
Page 220: ...Pattern Setup Results Errors Alarms TX300S_e manual_D07 00 064P_RevA00...
Page 260: ...TX300S_e manual_D07 00 064P_RevA00...
Page 261: ...Go back to top Go back to TOC Errors Alarms Page 2 TX300S_e manual_D07 00 064P_RevA00...
Page 369: ...OAM LMM Parameters OAM Service DMM OAM DMM Message TX300S_e manual_D07 00 064P_RevA00...
Page 374: ...Go back to top Go back to TOC TX300S_e manual_D07 00 064P_RevA00...