Copy Menu Options
Coupled:
TX and RX configurations are grouped as one block; TX and RX will have identical configuration. To uncouple
TX and RX settings, tap on the blue "Coupled" heading and select Independent from the Copy Menu.
Tx=Rx:
Tx blocks will copy the settings made in the Rx blocks
Rx=Tx:
Rx blocks will copy the settings made in the Tx blocks
Changes to the Setup are applied immediately unless an invalid parameter has been selected.
When the TX and RX signal structures need to be independent or asymmetrical, uncoupling the transmitter and receiver is
possible. For example, the TX could be sending a PRBS of 2^23-1 in a VC12 carried within an optical STM-64, while the RX
could be expecting to receive a PRBS of 2^23-1 in a 2Mbps E1 signal.
Hierarchy:
Allows the user to configure OTN/SDH, OTN/SONET, PDH signal and network types, including the bit rate and higher
order mapping, if applicable.
Interface:
Allows the user to select optical or electrical test ports. Optical test ports apply to OTN/SDH signal types only, while
electrical ports can apply to STTM-1E or PDH signals. Clock source and offset options are also configured in this screen.
Structure:
Applies to SDH/SONET signals only and allows the user to configure lower order mapping and the channel number.
Payload:
Applies to both SDH/SONET and PDH signals and allows the user to configure low rate signal (if applicable) and
associated framing.
Pattern:
Applies to both SDH/SONET and PDH signals and allows the user to configure the test pattern to be used. Use the
pattern drop-down box to select the test pattern which will be inserted into the transmitted signal. Pseudo Random Bit
Sequences (PRBS) defined by ITU-T 0.150 and 0.151 standards, fixed words and 24-bit or 32 bit user defined patterns are
available. Note, if the 32 bit user pattern entered is incorrect, the default pattern will be 0xFFFFFFFF.
Warning Message
While a test is running, it is possible to view the signal configuration, but it is not possible to change the setup or modify other
measurement settings. This warning screen is only shown during initial setup to alert the user.
Warning Message
TX300S_e-manual_D07-00-064P_RevA00
Summary of Contents for VePAL TX300M
Page 1: ...TX300S_e manual_D07 00 064P_RevA00...
Page 12: ...23 0 About VeEX Go back to top TX300S_e manual_D07 00 064P_RevA00...
Page 29: ...Go back to top Go back to TOC TX300S_e manual_D07 00 064P_RevA00...
Page 47: ...Go back to top Go back to TOC TX300S_e manual_D07 00 064P_RevA00...
Page 58: ...Go back to top Go back to TOC TX300S_e manual_D07 00 064P_RevA00...
Page 61: ...Tx Structure Setup Graphical Mode Tx Payload Setup TX300S_e manual_D07 00 064P_RevA00...
Page 71: ...Go back to top Go back to TOC TX300S_e manual_D07 00 064P_RevA00...
Page 92: ...TX300S_e manual_D07 00 064P_RevA00...
Page 126: ...TX300S_e manual_D07 00 064P_RevA00...
Page 182: ...Go back to top Go back to TOC TX300S_e manual_D07 00 064P_RevA00...
Page 220: ...Pattern Setup Results Errors Alarms TX300S_e manual_D07 00 064P_RevA00...
Page 260: ...TX300S_e manual_D07 00 064P_RevA00...
Page 261: ...Go back to top Go back to TOC Errors Alarms Page 2 TX300S_e manual_D07 00 064P_RevA00...
Page 369: ...OAM LMM Parameters OAM Service DMM OAM DMM Message TX300S_e manual_D07 00 064P_RevA00...
Page 374: ...Go back to top Go back to TOC TX300S_e manual_D07 00 064P_RevA00...