APS Test Procedure:
The TX300/e should be connected to a tributary port of network element or transmission system to ensure that the
switching time is measured for the service transported by the SONET network.
Ensure that no errors or alarms are present on the transmission system because this will impact the measurement.
The measurement will be triggered by an Alarm Indication Signal (AIS)
The TX300/e measures how long the AIS event remains present after the event is first recognized and will continue to
measure the total disruption time in the event of multiple disruptions.
10.2.7.2 APS Sequence
The associated K1/K2 sequence and received K1/K2 bytes may be captured.
TX300S_e-manual_D07-00-064P_RevA00
Summary of Contents for VePAL TX300M
Page 1: ...TX300S_e manual_D07 00 064P_RevA00...
Page 12: ...23 0 About VeEX Go back to top TX300S_e manual_D07 00 064P_RevA00...
Page 29: ...Go back to top Go back to TOC TX300S_e manual_D07 00 064P_RevA00...
Page 47: ...Go back to top Go back to TOC TX300S_e manual_D07 00 064P_RevA00...
Page 58: ...Go back to top Go back to TOC TX300S_e manual_D07 00 064P_RevA00...
Page 61: ...Tx Structure Setup Graphical Mode Tx Payload Setup TX300S_e manual_D07 00 064P_RevA00...
Page 71: ...Go back to top Go back to TOC TX300S_e manual_D07 00 064P_RevA00...
Page 92: ...TX300S_e manual_D07 00 064P_RevA00...
Page 126: ...TX300S_e manual_D07 00 064P_RevA00...
Page 182: ...Go back to top Go back to TOC TX300S_e manual_D07 00 064P_RevA00...
Page 220: ...Pattern Setup Results Errors Alarms TX300S_e manual_D07 00 064P_RevA00...
Page 260: ...TX300S_e manual_D07 00 064P_RevA00...
Page 261: ...Go back to top Go back to TOC Errors Alarms Page 2 TX300S_e manual_D07 00 064P_RevA00...
Page 369: ...OAM LMM Parameters OAM Service DMM OAM DMM Message TX300S_e manual_D07 00 064P_RevA00...
Page 374: ...Go back to top Go back to TOC TX300S_e manual_D07 00 064P_RevA00...