Electrical connection
5816,0013US / Version 02
47
8.3
Connecting the mains supply
Electrical voltage
DANGER
Danger to life from electric shock!
If the mains supply is not connected to the terminal
clamps correctly, loosens from the terminal clamps
and touches the housing or door, there is a direct
danger to life from electric shock.
– Have work at the electrical system only
performed by electricians.
– Connect mains supply according to the
following description.
– Install electrical protective devices according to
chapter 9.2, national and local codes.
– Perform proper grounding.
NOTE!
Cross-section of field wires used for mains line
shall comply with requirements of National Electric
Code (NFPA 70) and any applicable Local Codes.
DANGER!
Mortal danger by electric voltage!
1.
Disconnect barrier system power supply. Ensure that the
system is powered down. Secure against reactivation.
Strip-off cable and core insulation –
preparation of the wiring
2.
Strip-off mains supply and cores according to the following
figure.
Mag00201
0.79
(20)
0.31
(8)
1.18
(30)
0.31
(8)
2
3
1
Fig. 13: Strip-off the mains supply
Dimensions in inch or feet are without parenthesis.
Dimensions in mm are in parenthesis
1 Phase
2 Neutral
conductor
3 Ground
conductor