Malfunctions
78
5816,0013US / Version 02
Number
Description
Possible cause
Corrective action
8130
WARNING
Note monitoring
Communication with a plug
module was interrupted.
Check if all plugged
modules are listed in the
main menu.
Perform reset.
See
page 81, chapter 12.4.
Contact service if required.
Table 11: Event, warning and error messages – logic control (control unit)
12.3.2
Event, warning and error messages – Motor GW
Number
Description
Possible cause
Corrective action
2220
WARNING
Overcurrent
Overcurrent was recognised
Warning may appear in
connection with impact.
If no impact took place,
check the cables.
Contact service if required.
3211
WARNING
Overvoltage
Overvoltage
was
recognised
Warning may appear in
connection with impact.
If no impact took place,
check the cables.
Contact service if required.
3221
WARNING
Undervoltage Undervoltage
was
recognised
Check wiring.
Check if there is an overload
of the 24 V DC-supply.
Supply additional consumer
via separate mains unit.
If required, contact Service.
4210
WARNING
Overtemperature
A high temperature was
recognised.
Check motor temperature
via display. The temperature
must be below 100 °C.
See separate document
"Description of control units
MGC and MGC Pro for
MHTM
TM
MicroDrive
barriers", chapter "Motor
GW".
Contact service if required.
4220
WARNING
Derating error
Motor power intake is reduced
to avoid further temperature
increase.
Remove impermissible
attachments
Reduce speed of the barrier
arm.
Contact service if required.
Traffic H1 Swing Gate Horizontal Barrier