Technical data
5816,0013US / Version 02
31
4.3
Plug-in module "Detector A–B"
Designation
Unit
Plug-in module "Detector A–B"
Current consumption
mA
50
Number of loop detectors
─
2 (A and B)
Inductance range
H
70 to 500
Number of induction loop
sensitivity levels
─
10 levels
Response sensitivity
induction loop
%
Selectable: 0.01 to 2.0
Table 6: Plug-in module "Detector A–B"
4.4
Plug-in module "Radio"
Designation
Unit
Plug-in module "Radio"
Current consumption
mA
20
Frequency hand transmitter
MHz
433
HF-Modulation
–
FM/AM (depending on region)
Grant of equipment
authorization (Certificate)
–
FCC Identifier: QV2-SMD-53200RX
FCC 02-157
See page 89, chapter 15.
Table 7: Plug-in module "Radio"
Traffic H1 Swing Gate Horizontal Barrier
www.TURNSTILES.us | [email protected] | 303-670-1099