Electrical connection
5816,0013US / Version 02
49
8.4
Connect customer's control lines (signalling devices)
Lever system – crushing and
shearing danger
WARNING
Crushing and shearing danger from the lever
system!
The lever system can severely injure a person!
– Switch off power supply and secure against re-
activation before performing any work.
– When working in the area of the lever system,
ensure that the barrier does not start up
unexpectedly, e.g. by a control command or due
to wind.
– Secure the barrier arm so that unexpected
movement of the barrier arm e.g. by wind or
human force is not possible.
Placing the control lines
NOTE
Damage to the control lines!
Control lines that have been improperly placed and
attached may be caught and damaged by the
levers of the lever system.
– Place and attach control lines according to the
The following connections are available for control and feedback
on customer’s side:
8 Digital inputs for controlling the barrier.
4 Digital outputs to feed back information.
6 Relays outputs to feed back information. 3 Relays are
normally-open contacts (NO) and 3 relays are change-over
contacts.
DANGER!
Mortal danger by electric voltage!
1.
Disconnect barrier system supply voltage. Ensure that there is
no voltage applied. Secure against reactivation.
WARNING!
Danger of crushing at the lever system!
2.
Disassemble the safety plates in the area of the lever system
and remove them.