Malfunctions
5816,0013US / Version 02
75
Malfunction:
Barrier closes, although a vehicle is standing on the
safety loop.
Possible cause
Corrective action
Removal by
Option "Monitoring" for the
parameters "Mode A" or "Mode B" not
selected in the menu "Loop detector
1 (A-B)".
Select option "Monitoring".
MHTM MicroDrive
service specialist
Cut off angle incorrectly
parameterised.
Check and adjust the cut off angle.
MHTM MicroDrive
service specialist
Too low trigger sensitivity set for the
loop.
Check the response sensitivity of the
loop and adjust if necessary.
MHTM MicroDrive
service specialist
Unsuitable loop geometry installed.
Install appropriate loop geometry.
MHTM MicroDrive
service specialist
Loop fault due to external loop
detectors or other barriers in the
proximity.
Check the operating frequency of the
loops and adjust if necessary
MHTM MicroDrive
service specialist
Retrofit signal light, such as
red/green signal light and
parameterise lead time.
MHTM MicroDrive
service specialist
User misbehaviour e.g. driving into
closing barrier, or following behind
another vehicle.
Upgrade signs.
Operator
Malfunction:
Menu items of the plug-in modules, such as
"Detector 1 (A-B) are displayed but cannot be operated.
Possible cause
Corrective action
Removal by
The SW version of the plug-in module
is lower than 0.10. The SW version is
displayed in the respective menu in
the submenu "Information".
Use plug-in module with a SW
version 0.10 and up.
Perform update to SW version
0.12.
MHTM MicroDrive
service specialist
Malfunction:
The menu language of the plug-in module is English
although another language was set.
Possible cause
Corrective action
Removal by
The SW version of the plug-in module
is 01.10. The SW version is displayed
in the respective menu in the
submenu "Information".
Perform update to SW version 0.12.
MHTM MicroDrive
service specialist
Traffic H1 Swing Gate Horizontal Barrier