Assembling flange and barrier arm
56
5816,0013US / Version 02
9.2
Check swivel range, set close direction and mount flange
1.
Secure barrier danger area e.g. with barrier tape.
2.
Remove rear cover of the barrier housing.
3.
Remove rear door of the barrier housing.
4.
Switch on power supply.
5.
Switch on the barrier if required.
Switch on Mode "Service "
6.
Switch the "Service" switch on the control unit. The LED lights
red. The display backlighting flashes.
Check the swivel range of the
barrier arm
7.
Opening and closing the barrier manually; Check the swivel
range via the shaft.
Middle left button : Manually open the barrier.
Middle right button
: Manually close the barrier.
Setting the close direction
8.
If the close direction is incorrect, change the close direction
via the parameter "Close direction".
See separate
document "Description of control units MGC and MGC Pro for
MHTM
TM
MicroDrive barriers", chapter "Close direction".
WARNING!
Danger of crushing between flange and barrier housing!
9.
Switch off power supply. Ensure that the system is powered
down. Secure against reactivation.
Traffic H1 Swing Gate Horizontal Barrier
www.TURNSTILES.us | [email protected] | 303-670-1099