Technical data
30
5816,0013US / Version 02
4.2
Control unit
Designation
Unit
MGC
(MAGNETIC Gate Controller)
Supply voltage
V DC
24
Current consumption
─
max. 1 A,
max. 300 mA + current
consumption of the different plug-in
modules
Power consumption
─
max 24 W,
Max. 7.2 W + power consumption
of the different plug-in modules
Control unit safety
─
1 A T
Output voltage
V DC
24
Output clamp X2
Max. output current
mA
300
Number
─
8
Input voltage
V DC
24 ± 10 %
Input current
─
< 10 mA per input
Digital inputs
Max. line length without
overvoltage module
1)
ft (m)
100 (30)
Number
─
4 (open collector)
Switching voltage
V DC
24 ± 10 %
Max. switching current
mA
100
Digital outputs
Max. line length without
overvoltage module
1)
ft (m)
100 (30)
Number
─
3 normally-open contact and
3 change-over contacts, isolated
Max. switching voltage
V AC / DC
30
Switching current
mA
10 mA to 1 A
Output relay
Max. line length without
overvoltage module
1)
ft (m)
100 (30)
Display
─
Graphics display, 128 x 65 Pixel
Language display
─
Selectable: German, English,
French, Spanish, Italian,
Portuguese, Swedish, Finnish,
Norwegian, Danish, Estonian,
Dutch
Number of slots for plug-in modules
─
5
1) For line lengths exceeding 30 m, overvoltage modules must be installed in front of the terminal clamps.
Table 5: Control unit
Traffic H1 Swing Gate Horizontal Barrier
www.TURNSTILES.us | [email protected] | 303-670-1099