Cleaning and maintenance
70
5816,0013US / Version 02
Interval
Maintenance work
To be carried out by
Perform all monthly and semi-annual maintenance
work.
Electrician /
specialist
Check the barrier's mechanics.
Check barrier arm position.
Visual inspection of the induction loops and the
carriageway in the area of the loops for damage.
Check the induction loops' function.
See separate document "Description of control
units MGC and MGC Pro for MHTM
TM
MicroDrive
barriers", chapter "Detector 1 (A-B)".
Check the induction loops. Measure the contact
resistance, insulation resistance, and inductivity of
the induction loops.
Where they exist, check the function of additional
safety equipment, such as safety scanners.
Check the barrier's function.
Check the barrier's locking in both end positions.
Check the advanced warning on barriers with the
active function "Traffic lights lead".
Check electric cables for damages.
Check if all electrical connections are firm.
Every 12 months
Check signs and labels for completeness and
legibility.
MHTM MicroDrive
service specialist
Table 10: Maintenance schedule
Traffic H1 Swing Gate Horizontal Barrier
www.TURNSTILES.us | [email protected] | 303-670-1099