Malfunctions
5816,0013US / Version 02
73
Malfunction:
Barrier does not close. The message "Waiting for
release" appears on the display.
Possible cause
Corrective action
Removal by
The message appears after the
power supply is switched on, after
voltage returns and after reset.
The release signal can be given by
an external closing signal or by
pushing the left operating button at
the control unit.
See separate
document "Description of control
units MGC and MGC Pro for MHTM
TM
MicroDrive barriers", chapter "Start-
up settings".
Operator
Malfunction:
Barrier does not close. The message "Waiting for
passage" appears on the display.
Possible cause
Corrective action
Removal by
The message appears after the
power supply is switched on, after
voltage returns and after reset.
The barrier closes once a vehicle
passes.
See separate
document "Description of control
units MGC and MGC Pro for
MHTM
TM
MicroDrive barriers",
chapter "Start-up settings".
Confirm message with the left
button at the control unit.
Operator
Malfunction:
Barrier does not close. The display shows:
Possible cause
Corrective action
Removal by
Loop not connected.
Connect loop
MHTM MicroDrive
service specialist
Detector mode incorrectly
parameterised.
Check parameterisation of the
detector module and correct if
required.
See separate document
"Description of control units MGC and
MGC Pro for MHTM
TM
MicroDrive
barriers", chapter "Detector 1 (A-B)".
MHTM MicroDrive
service specialist
Loop defective.
Replace loop.
MHTM MicroDrive
service specialist
Transfer resistance at the terminals
Cut connecting leads, strip and
connect them again without end
sleeves.
MHTM MicroDrive
service specialist
Traffic H1 Swing Gate Horizontal Barrier
www.TURNSTILES.us | [email protected] | 303-670-1099