background image

Assembling flange and barrier arm 

58 

5816,0013US / Version 02 

 

9.3 

Mount the barrier arm and the anchor support 

NOTE! 
Depending on equipment of the barrier arm and its 
weight, we recommend installing the barrier arm 
with two people. 

Prerequisites 

The danger area is secured with barrier tape.

The flange is installed.

The swivel range of the barrier arm is known.

WARNING! 
Danger of crushing between barrier arm and barrier housing! 

1.

Switch off power supply. Ensure that the system is powered
down. Secure against reactivation.

Mount barrier arm 

2.

Push the barrier arm onto the flange.

3.

Mount the barrier arm on the flange via the screws.

Torque wrench: 8 AF

Tightening torque: 8.8 lbf ft (12 Nm)

Mag00514a

1

2

Fig. 19: Mounting the barrier arm 

Traffic H1 Swing Gate Horizontal Barrier

www.TURNSTILES.us | [email protected] | 303-670-1099

Summary of Contents for Traffic H1

Page 1: ...Operating Instructions Traffic H1 Swing Gate Horizontal Barrier www TURNSTILES us patrick mcallister TURNSTILES us 303 670 1099...

Page 2: ...us Inc 8641 S Warhawk Road Conifer CO 80433 USA Tel 1 303 670 1099 E Mail patrick mcallister TURNSTILES us Internet www TURNSTILES us Traffic H1 Swing Gate Horizontal Barrier www TURNSTILES us patric...

Page 3: ...e should cross the path of a moving barrier arm Test the barrier system monthly After adjusting the force or the limit of travel retest the barrier system Failure to adjust and retest the barrier syst...

Page 4: ...4 5816 0013US Version 02 www TURNSTILES us patrick mcallister TURNSTILES us 303 670 1099 Traffic H1 Swing Gate Horizontal Barrier www TURNSTILES us patrick mcallister TURNSTILES us 303 670 1099...

Page 5: ...difications 17 2 4 Specialists and operating personnel 18 2 4 1 Requirements 18 2 5 Personal protective equipment 19 2 6 Occupational safety and special dangers 19 2 6 1 Danger symbols on the MHTMTM M...

Page 6: ...4 1 Connecting safety loops and or safety scanners 50 8 4 2 Connecting safety loop 51 8 4 3 Connecting testable safety devices and test them 52 8 4 4 Connecting emergency opening contacts 52 8 4 5 Di...

Page 7: ...ontrol unit 76 12 3 2 Event warning and error messages Motor GW 78 12 3 3 Event warning and error messages Detector 80 12 3 4 Event warning and error messages All modules 80 12 4 Reset the barrier 81...

Page 8: ...8 5816 0013US Version 02 Traffic H1 Swing Gate Horizontal Barrier www TURNSTILES us patrick mcallister TURNSTILES us 303 670 1099...

Page 9: ...ting any work They are a product component and must be kept in direct proximity of the barrier well accessible to the personnel at all times When passing the barrier on to third parties the operating...

Page 10: ...or severe injuries if it is not avoided WARNING The signal word WARNING points to a potentially dangerous situation which can lead to death or severe injuries if it is not avoided CAUTION The signal w...

Page 11: ...erms and conditions as well as the manufacturer s conditions of delivery and the statutory provisions valid at the time of contract conclusion shall apply In no event shall manufacturer be liable for...

Page 12: ...l and electrical components of the product to the extent as stated in its standard terms of sales and delivery or as contractually agreed in writing We makes no warranties express or implied regarding...

Page 13: ...rier In case of improper disposal of components or the barrier damage to the environment may result Observe the local and national laws and directives Disassemble barrier according to resources Sort r...

Page 14: ...m protection level in the industrial area the entire swivel range of the barrier arm must be monitored by a contact free safety device We recommend using safety laser scanners as a safety device In th...

Page 15: ...sufficiently large metal areas in the vehicle floor area to enable detection by induction loops Other or complementary safety facilities must be provided for road vehicles that cannot be detected by i...

Page 16: ...c rail transport system for shutting off rail bound vehicles is not permitted The barriers are not approved for pedestrian traffic bicycles or animals The barriers must not be used in explosive enviro...

Page 17: ...all employees that are working at or with the barrier have read and understood the operating instructions Furthermore the operator must train personnel regarding the use of the barrier at regular inte...

Page 18: ...of the relevant standards and regulations to execute tasks on electrical systems and to independently recognize possible hazards In Germany the electrical specialist must comply with the provisions o...

Page 19: ...s areas on the barriers can be identified by the following pictograms Electric voltage DANGER Mortal danger by electric voltage indicates life threatening situations caused by electric voltage Non obs...

Page 20: ...n or to individual components can be lethal Switch off the power supply immediately in case of damage to the insulation and arrange repair Only electrical specialists may carry out work on the electri...

Page 21: ...barrier includes mortal danger Never install the barrier housing and barrier arm during thunderstorms Protect yourself in buildings or vehicles Improper operation WARNING Danger from improper operati...

Page 22: ...of the barrier arm is monitored with a contact free safety device such as a safety scanner The safety device for recognition of the presence of persons and animals must be sized and installed so that...

Page 23: ...ed set up separate passageway for persons and bicycles Before any movement of the barrier arm such as closing and opening persons and the flowing traffic must be stopped by the corresponding signals s...

Page 24: ...d be done by at least two people Heavy weight WARNING Risk of injury when lifting heavy objects alone The weight of heavy objects can severely injure a person Lifting and carrying the barrier arm and...

Page 25: ...ange WARNING Danger of crushing between barrier arm and barrier housing Moving parts may cause serious crushing injuries Only skilled personnel are allowed to work on the barrier housing and barrier a...

Page 26: ...e crushing or injury Keep a distance of at least 2 ft 610 mm between the barrier arm and other objects such as walls masonry or houses Install the barrier system only when all exposed pinch points are...

Page 27: ...3 Power supply Frequency 4 Nominal current consumption max peak current consumption additional current consumption when using the service socket 5 Power consumption 6 Operating time Opening time closi...

Page 28: ...30 7 780 min 2 ft min 610 Fig 6 Dimensions barrier system and barrier arm profile Dimensions in inch or feet are without parenthesis Dimensions in mm are in parenthesis 1 Object such as wall building...

Page 29: ...uty cycle 100 1 The values refer to a power supply of 120 V AC 60 Hz and without accessories Table 2 Electrical connection Traffic series 4 1 2 Operating conditions Designation Unit Traffic H1S Traffi...

Page 30: ...hing voltage V DC 24 10 Max switching current mA 100 Digital outputs Max line length without overvoltage module 1 ft m 100 30 Number 3 normally open contact and 3 change over contacts isolated Max swi...

Page 31: ...induction loop Selectable 0 01 to 2 0 Table 6 Plug in module Detector A B 4 4 Plug in module Radio Designation Unit Plug in module Radio Current consumption mA 20 Frequency hand transmitter MHz 433 H...

Page 32: ...both end positions In case of power outage the barrier arm can easily be moved by hand Sensors integrated in the motor supply exact data on every correct position of the barrier arm and thus serve th...

Page 33: ...ry when lifting heavy objects alone The weight of heavy objects can severely injure a person Lifting and carrying the barrier arm and housing from the pallet should be done by a minimum of two people...

Page 34: ...t for each defect as soon as it is recognized Compensation claims can only be submitted within the valid complaint periods 6 3 Transport Barrier housing and barrier arm are delivered separately The li...

Page 35: ...gressive media Protect against solar irradiation Avoid mechanical vibrations Storage temperature 22 to 158 F 30 to 70 C Relative humidity max 95 non condensing Check the general condition of all compo...

Page 36: ...oosely stacked or lying around components and tools are accident sources Comply with specifications for foundations and reinforcement Ensure correct arrangement and fit on all assemblies and component...

Page 37: ...0 2 Mag00547a min 2 ft min 600 t t Fig 8 Assembly barrier system Dimensions in inch or feet are without parenthesis Dimensions in mm are in parenthesis 1 Object such as wall building etc Keep a safety...

Page 38: ...y concrete foundations C35 45 XD3 XF2 Water cement value 0 5 Foundation depth at least 31 5 in 800 mm frost protected foundation depth to be adjusted to the local situation Foundation section 17 7 in...

Page 39: ...y conduit for induction loop diameter 1 14 in 29 mm 4 Empty conduit for control lines diameter 1 14 29 mm 5 Concrete foundations C35 45 XD3 XF2 6 Roadway 7 Foundation depth at least 31 5 in 800 mm fro...

Page 40: ...lution such as Sikagard 703 W or deepdry to the concrete surface before housing assembly Moisture protection prevents entering of moisture into the housing from the concrete floor 7 4 Unpacking The in...

Page 41: ...hoods and two doors Rear cover and rear door 1 Unlock the lock at the rear door 2 Fold the rear cover up and remove it 3 Pull out the door upwards Front cover and front door 4 Unlock the lock at the...

Page 42: ...7 Foundation anchor 8 Foundation 9 Silicon sealant 2 Drill holes for the foundation anchors according to the foundation plan page 39 Fig 9 in compliance with the indicated sizes Drill hole distance 7...

Page 43: ...points must be checked after assembly and installation of the barrier Are all foundation anchors firmly fixed Are all screws firmly tightened Have all barrier housing covers been properly assembled Tr...

Page 44: ...g knowledge and experiences as well as knowledge of the relevant standards and regulations to execute tasks on electrical systems and to independently recognize possible hazards In Germany the electri...

Page 45: ...l connection is established during precipitation e g rain or snow penetration of moisture must be prevented by suitable measures such as a protective cover General WARNING Danger by inappropriate inst...

Page 46: ...and apply additional parts approved by MAGNETIC The electrical and electronically additional parts must be EMC verified and must not exceed the indicated EMC limits Personal protective equipment The...

Page 47: ...grounding NOTE Cross section of field wires used for mains line shall comply with requirements of National Electric Code NFPA 70 and any applicable Local Codes DANGER Mortal danger by electric voltage...

Page 48: ...e must be wired so that no damage could occur due to moving parts Attach mains supply to the metal tabs via 2 cable ties Mag00540 1 Fig 14 Mains supply placement 1 Mains supply 2 Cable tie 3 Cable tie...

Page 49: ...nes that have been improperly placed and attached may be caught and damaged by the levers of the lever system Place and attach control lines according to the following Figure Fig 16 The following conn...

Page 50: ...ng diagrams 5 Install the safety plates in the area of the lever system Mag00518a 1 2 3 4 Fig 16 Connecting the control lines 1 Control unit 2 Cable tie metal tabs 3 Cable opening 4 Cable clamps 8 4 1...

Page 51: ...2 B1 B2 3 2 1 Mag00519a Fig 17 Connecting safety loop 1 Control unit 2 Connection of induction loop A 3 Plug in module Detector 1 A B 4 Connection of induction loop B A Induction loop A B Induction lo...

Page 52: ...arrier opens While the signal is present the barrier cannot be closed See page 91 chapter 16 1 Wiring diagrams 8 4 5 Digital inputs Technical data See page 30 chapter 4 2 NOTE The digital input functi...

Page 53: ...Boom angle 60 85 NO6 NC6 Relay 6 Service mode active Table 9 Factory settings Digital outputs and Relay outputs 8 5 Checking the electrical connection The following points have to be checked after th...

Page 54: ...mponents and tools are accident sources Ensure correct arrangement and fit of all assemblies and components Install the indicated fastening elements correctly Danger of crushing and shearing barrier a...

Page 55: ...The end stop for the barrier arm is set to a swivel angle of 90 ex works The barrier arm is locked at the ends at 90 only At smaller swivel angles the barrier arm may be pushed out e g by wind or no...

Page 56: ...k the swivel range of the barrier arm 7 Opening and closing the barrier manually Check the swivel range via the shaft Middle left button Manually open the barrier Middle right button Manually close th...

Page 57: ...14 Switch the Service switch on the control unit The LED lights red The display backlighting flashes 15 Opening and closing the barrier manually Check the swivel range again via the flange Middle lef...

Page 58: ...wivel range of the barrier arm is known WARNING Danger of crushing between barrier arm and barrier housing 1 Switch off power supply Ensure that the system is powered down Secure against reactivation...

Page 59: ...20 Scope of delivery anchor support 1 Bolts 2 Turnbuckles 3 Spiral rope with thread terminal and counter nuts 4 Anchoring axle 5 Side parts 2 6 Hexagon screws M10 8 7 Screws M8 with safety discs 8 ea...

Page 60: ...21 Mounting the side parts and the anchoring axle 5 Mount anchor support on top Proceed as follows for this Turn threaded terminal into the upper axle about half NOTICE To avoid destruction of the an...

Page 61: ...ecure it with the safety pin Mag00516a 1 2 3 4 Fig 24 Mounting the lower anchor support 9 Move the clamp holder until the spiral rope is slightly tensed 10 Tighten the 8 screws of the clamp holder Tor...

Page 62: ...works ensure that all housing covers are correctly mounted Wind forces over 10 Beaufort WARNING Risk of injury from breaking off barrier arms in case of high wind speeds In case of wind speeds exceed...

Page 63: ...program mode See separate document Description of control units MGC and MGC Pro for MHTMTM MicroDrive barriers chapter Select programme mode Check parameterisation in connection with wiring Testing a...

Page 64: ...r door of the barrier housing 3 Switch on the barrier via the double pole mains switch 4 Depending on the settings in the Start up behaviour menu the barrier arm slowly moves into the end position hom...

Page 65: ...he LED lights red The display backlighting flashes 2 Perform one of the following functions Push middle left button Manually open the barrier Push middle right button Manually close the barrier 3 Swit...

Page 66: ...the barrier with mains voltage Remove the barrier arm if necessary NOTICE Possible damage to the equipment by condensed water when mains voltage is switched off Keep supplying the barrier with mains...

Page 67: ...e Pay attention to tidiness and cleanness at the assembly site Loosely stacked or lying around components and tools are accident sources After completion of maintenance work ensure that all covers are...

Page 68: ...nger from the lever system The lever system can severely injure a person Switch off power supply and secure against re activation before performing any work When working in the area of the lever syste...

Page 69: ...carried out by Visual inspection of the housing inside and out for damage and corrosion Clean the housing and repair paint damage as necessary Remove corrosion damage Specialist Visual inspection of...

Page 70: ...k the induction loops Measure the contact resistance insulation resistance and inductivity of the induction loops Where they exist check the function of additional safety equipment such as safety scan...

Page 71: ...roubleshooting Inappropriate troubleshooting can cause severe or lethal injuries All troubleshooting work must be performed by specialists or electronics specialists Observe possible movements of the...

Page 72: ...n Removal by Display contact set too light or dark Correct display contact See separate document Description of control units MGC and MGC Pro for MHTMTM MicroDrive barriers chapter Setting display con...

Page 73: ...ier closes once a vehicle passes See separate document Description of control units MGC and MGC Pro for MHTMTM MicroDrive barriers chapter Start up settings Confirm message with the left button at the...

Page 74: ...installed between the clamps X11 OUT and IN See page 91 chapter 16 1 MHTM MicroDrive service specialist Malfunction Barrier does not close immediately after through traffic but only after the hold ope...

Page 75: ...rofit signal light such as red green signal light and parameterise lead time MHTM MicroDrive service specialist User misbehaviour e g driving into closing barrier or following behind another vehicle U...

Page 76: ...To take the barrier into operation again the fault must be removed by an MHTM MicroDrive service specialist and a reset according to chapter 12 4 must be performed For requirements to the MHTM MicroDr...

Page 77: ...swivel range of the barrier arm anymore When no obstacle is present within the swivel range of the barrier arm check input e g contact strip 3120 ERROR Mains voltage fluctuations Short term mains outa...

Page 78: ...arning may appear in connection with impact If no impact took place check the cables Contact service if required 3221 WARNING Undervoltage Undervoltage was recognised Check wiring Check if there is an...

Page 79: ...OR HW Enable Test failed Contact service FF33 ERROR LS Test failed Test of the safety device failed Check safety device and connection FF36 WARNING Motor reset Homing is performed automatically A shor...

Page 80: ...G Loop error B or D Short circuit or idle loop B or D Remove loop error and perform adjustment If no loop is connected select the option Inactive in the menu Detector Table 13 Event warning and error...

Page 81: ...conds or Press the two middle operating buttons on the control unit display for 5 seconds NOTICE Damage to the unit by too short switching intervals of the mains voltage To avoid damage to the equipme...

Page 82: ...orking in the area of the lever system ensure that the barrier does not start up unexpectedly e g by a control command or due to wind Secure the barrier arm so that unexpected movement of the barrier...

Page 83: ...02 83 Mag00574 1 Fig 27 Push the lever system from the dead point 1 Slit in the safety sheet for long tools such as screwdrivers Traffic H1 Swing Gate Horizontal Barrier www TURNSTILES us patrick mcal...

Page 84: ...he address see invoice delivery note or the reverse of these instructions After completion of repair work ensure that all covers are correctly mounted Lever system crushing and shearing danger WARNING...

Page 85: ...tally A closing or opening barrier arm can cause severe injuries or property damage Observe the movement radius of the barrier arm Ensure freedom of movement Remove obstacles from the movement range N...

Page 86: ...s 11 Open and close the barrier manually to check the swivel range Middle left button Manually open the barrier Middle right button Manually close the barrier Sett close direction 12 If the close dire...

Page 87: ...osed of in an environmental friendly manner Decommissioning disassembly and disposal of the barrier may only be carried out by specialised staff Disassemble the barrier in reverse order from assembly...

Page 88: ...88 5816 0013US Version 02 Traffic H1 Swing Gate Horizontal Barrier www TURNSTILES us patrick mcallister TURNSTILES us 303 670 1099...

Page 89: ...Traffic H1 Swing Gate Horizontal Barrier www TURNSTILES us patrick mcallister TURNSTILES us 303 670 1099...

Page 90: ...90 5816 0013US Version 02 Traffic H1 Swing Gate Horizontal Barrier www TURNSTILES us patrick mcallister TURNSTILES us 303 670 1099...

Page 91: ...g diagrams Following wiring diagrams apply to standard barriers Observe the customer specific wire diagrams for customer specific barriers if applicable Traffic H1 Swing Gate Horizontal Barrier www TU...

Page 92: ...Appendix 92 5816 0013US Version 02 Traffic H1 Swing Gate Horizontal Barrier www TURNSTILES us patrick mcallister TURNSTILES us 303 670 1099...

Page 93: ...1 2 3 4 5 6 7 8 9 0 01 03 12 14 5K14528 gp 01 08 2014 gp Datum Name nderungsprojekt Version Steuerung Schleifen Option Motor Getriebe Anschlussplatte Traffic H1 Swing Gate Horizontal Barrier www TURNS...

Page 94: ......

Page 95: ...Motor Interface Kabel Hauptschalter Hauptanschlussklemmen Netzteil T1 X1 S1 1 2 3 4 S1 3460 5024 Spannungsversorgung Steuerung WH GN BN GN YE YE GY BK BN BU MIK 1 6 0 Zuleitung L L N N PE PE X1 L L N...

Page 96: ......

Page 97: ...ion schliessen geschlossen Baumwinkel 30 85 Schleife aktiv A Fehler ffnen bergeordnet schliessen ge ffnet Schleife aktiv B Servicemodus aktiv ffnen untergeordnet Baumwinkel 60 85 Aufschlagerkennung Ve...

Page 98: ......

Page 99: ...canner 50 Control unit Technical data 30 Control unit MGC 9 Control unit MGC Pro 9 Copyright 11 Cover Front 41 Rear 41 Customer service 12 D Danger area 26 Decommissioning 87 Temporarily 66 Design 32...

Page 100: ...sation 9 Personal protective equipment 19 Pictogram explanation 10 Power failure Moving the barrier arm 82 R Radio plug in module Technical data 31 Reinforcement 38 39 Replacing Barrier arm 85 Reset b...

Page 101: ...76 Warranty 12 Weight 29 Wiring diagrams 91 www TURNSTILES us Inc 8641 S Warhawk Road Conifer CO 80433 USA Tel 1 303 670 1099 E Mail patrick mcallister TURNSTILES us Internet www TURNSTILES us Traffi...

Reviews: