Traverse Installation and Commissioning Guide, Section 2: Network Interface Specifications
ECM Placement at the Traverse Main Backplane
Page 2-18
Turin Networks
Release TR3.2.1
ECM
Placement at
the Traverse
Main
Backplane
ECMs plug into the main backplane 2 mm connectors of any corresponding odd or
even slot. The n-slot ECM occupies the width of n slots on the main backplane.
•
2-Slot ECM
, page 2-18
•
3-Slot ECM
, page 2-19
2-Slot ECM
The 2-slot ECM occupies the width of two slots, as shown below. For example, the
ECM for slots 1 and 2 plugs into the 2 mm connectors for slot number 1 (n=1). The
ECM can plug into any odd or even slot, and the lowest slot in the pair is the protecting
slot. In the figures of the Traverse shelf below, all of the odd main backplane 2 mm
connectors are chosen and shown in dark gray. The outline of the 2-slot ECM for slots
1 and 2 is shown in light gray.
Figure 2-6 2-Slot ECM on a Traverse 1600 Backplane
Figure 2-7 2-Slot ECM on a Traverse 600 Backplane
2-slot ECM
Slot n=1
connectors
n
n+1
2-slot ECM
Slot n=1
connectors
n
n+1