Chapter 5 Ethernet (Electrical) Cabling Procedures
Plug-in 10/100BaseT Electrical Connector Module
Release TR3.2.1
Turin Networks
Page 8-43
Plug-in
10/100BaseT
Electrical
Connector
Module
10/100BaseT electrical connector modules are plugged into two 2 mm connectors on
the Traverse main backplane.
Follow these steps to plug-in 10/100BaseT electrical connector modules.
13
Use Category 5E twisted-pair patch cable between the patch panel and
Ethernet network equipment.
14
The Protected GbE TX and 10/100BaseTX Cabling at the ECM procedure
is complete.
Do you have other network interface connections?
•
Yes.
Repeat ECM and cabling connections for all network interfaces.
•
No.
Alarm, Timing, and Management Cabling
Table 8-15 Protected GbE TX and 10/100BaseTX Cabling at the ECM (continued)
Step
Procedure
Important:
Always wear a properly grounded Electrostatic Discharge
(ESD) wrist strap when making connections to the Traverse main
backplane.
Table 8-16 Plug-in 10/100BaseT Electrical Connector Module
Step
Procedure
1
Are 10/100BaseT electrical connector modules plugged into the main
backplane?
•
If yes, continue to the next procedure, Unprotected 10/100BaseTX
Cabling, Electrical Connector Module.
•
If no, continue to Step 2.
2
The Traverse shelf may have blank back covers in place over the 2 mm
connectors on main backplane. Remove the blank back covers from the
Traverse shelf as required for placement of ECMs.
Refer to
Precautions and Common Procedures
Chapter 2—“Removing and Replacing Back Covers” for detailed
instructions.
3
Line up a 10/100BaseT electrical connector module with two 2 mm
connectors on the main backplane.
Note:
The ECM is placed in the right-most connectors (as viewed from
the back of the shelf). Refer to Section 2—
, Chapter 5—“Ethernet (Electrical) Interface Cabling