[6] Troubleshooting
NOTE
: Do not touch the SET button
on the servo amplifier in the inverter box. Doing so may damage the internal
settings.
(1) If the “Terry motion Alarm” message appears on the function panel and the machine will not run (The yellow lamp
of the signal indicator flashes):
Any alarm code on the servo amplifier operation display in the inverter box?
↓
YES
↓
NO
Remove whatever caused error (referring to the next
page), press the ALARM RESET button, and then
start the machine.
1
.
If the CHARGE LED (red) of the servo amplifier
is off, it means that:
・
no 3-phase 200-V power is supplied to the servo
amplifier CN6 terminals R, S and T,
or
・
the servo amplifier is defective. (Replace it.)
2
.
The wiring between the weaving machine and
inverter box is broken.
E5. Electronic Terry Motion