How to Check the Effective Load Ratio bL
・
In the initial display state, keep pressing
▼
until "
bL___" is displayed.
・
Check the maximum value during terry motion
operation.
[2] Installation
Powering on the weaving machine after wiring between the machine and the inverter box will turn on the ZERO
POSITION ALARM LED (PL2) located in the inverter box, as well as displaying alarm 23 or 32 on the servo amplifier
7-segment display. This is because the cable between the servomotor and servo amplifier was disconnected at the time of
shipment. Therefore, you need to register the zero point according to the procedure below.
■
Zero Point Registering Procedure
(1) The ZERO POSITION ALARM LED comes on.
↓
(2) Alarm 23 appears on the servo amplifier display.
↓
(3) Press the ALARM RESET button.
↓
(4) Turn the machine power off. After at least 10 seconds, turn it on.
↓
(5) Alarm 32 appears on the servo amplifier display.
↓
(6) Press the ALARM RESET button.
↓
(7) Set the MANUAL-AUTO switch to the MANUAL position.
↓
(8) Turn the FWD-REV switch until the zero-point restoration proximity switch LED comes on.
First, turn the proximity switch in the FWD direction to shift the cloth fell forwards by approx. 10 mm.
Then, turn it in the REV direction until the zero-point restoration switch LED comes on.
↓
(9) Press the ZERO POSITION button. After a few seconds, check that the ZERO POSITION ALARM LED
goes off.
↓
(10) Turn the MANUAL-AUTO switch to the AUTO position.
↓
(11) Check that the ZERO POSITION LED is on and the zero-point restoration switch LED is off.
E5. Electronic Terry Motion
99