![Toshiba TOSVERT VF-FS1 Series Instruction Manual Download Page 99](http://html.mh-extra.com/html/toshiba/tosvert-vf-fs1-series/tosvert-vf-fs1-series_instruction-manual_425671099.webp)
E6581381
F-3
6
Output frequency [Hz]
Time [s]
Designated frequency
−
H
ON
OFF
Designated frequency
+
H
Designated frequency
Set frequency speed reach signal
RY-RC
FLA/FLC/FLB
Set frquency spped reach signal:
Inverted
ON
OFF
0
6.1.3 Output of set frequency speed reach signal
H
: Speed reach setting frequency
H
: Speed reach detection band
•
Function
When the output frequency becomes equal to the frequency set by
H
±
H
, an ON or
OFF signal is generated.
[Parameter setting]
Title
Function
Adjustment range
Default setting
H
Speed reach setting frequency
0.0
∼
HJ
(Hz)
0.0
H
Speed reach detection band
0.0
∼
HJ
(Hz)
2.5
[Parameter setting]
Title
Function
Adjustment range
Setting value
H
Output terminal
selection 1A
(RY-RC)
0-255
(
⇒
See page K-17)
8: RCHF (designated frequency - ON
signal), or
9: RCHFN (designated frequency -
OFF signal)
Note: Select the
H
parameter function No. 8 or 9 to specify FLA-FLC-FLB terminal output.
Summary of Contents for TOSVERT VF-FS1 Series
Page 2: ......
Page 15: ...E6581381 A 3 1 1 3 Names and functions 1 3 1 Outside view Operation panel ...
Page 18: ...E6581381 A 6 1 VFFS1 2004 2037PM VFFS1 4004 4055PL Note EMC plate is supplied as standard ...
Page 36: ......
Page 40: ...E6581381 B 4 2 2 2 2 Standard connection diagram 2 ...
Page 54: ......
Page 56: ...E6581381 D 2 4 4 1 Flow of status monitor mode Flow of monitor as following ...
Page 66: ......
Page 180: ......
Page 196: ......
Page 208: ......
Page 233: ...E6581381 L 5 12 Outline drawing Fig A Fig B Fig C Fig D ...
Page 242: ......
Page 248: ......
Page 251: ......