![Toshiba TOSVERT VF-FS1 Series Instruction Manual Download Page 133](http://html.mh-extra.com/html/toshiba/tosvert-vf-fs1-series/tosvert-vf-fs1-series_instruction-manual_425671133.webp)
E6581381
F-37
6
6.12.5 Output voltage adjustment/Supply voltage correction
XNX
: Base frequency voltage 1
H
: Supply voltage correction (output voltage adjustment)
•
Function
Base frequency voltage1
The
H
parameter adjusts the voltage corresponding to the base frequency 1
XN
so that no
voltage exceeding the
XNX
set value is put out. (This function is enabled only when
H
is set
to either "0" or "1".)
Supply voltage correction
The
H
parameter maintains a constant V/F ratio, even when the input voltage decreases. The
torque during low-speed operation is prevented from decreasing.
Supply voltage correction: Maintains a constant V/F ratio, even when the input voltage fluctuates.
Limitation of output voltage: Limits the voltage at frequencies exceeding the base frequency. Applied when
operating a special motor with low induced voltage.
[Parameter setting]
Title
Function
Adjustment range
Default setting
XNX
Base frequency voltage1
50-330 (V) : 200V class
50-660 (V) : 400V class
230 (WP/WN type)
400 (WP type)
460 (WN type)
H
Supply voltage correction
(limitation of output voltage)
0: Supply voltage uncorrected,
output voltage limited
1: Supply voltage corrected,
output voltage limited
2: Supply voltage uncorrected,
output voltage unlimited
3: Supply voltage corrected,
output voltage unlimited
2
+
If
H
is set to "
" or "
", the output voltage will change in proportion to the input voltage.
+
Even if the base frequency voltage (
XNX
parameter ) is set above the input voltage, the output voltage
will not exceed the input voltage.
+
The rate of voltage to frequency can be adjusted according to the rated motor capacity. For example,
setting
H
to "
" or "
" prevents the output voltage from increasing, even if the input voltage
changes when operation frequency exceeds the base frequency.
+
When the V/F control mode selection parameter (
RV
) is set to any number between
and
, the supply
voltage is corrected regardless of the setting of
H
.
Summary of Contents for TOSVERT VF-FS1 Series
Page 2: ......
Page 15: ...E6581381 A 3 1 1 3 Names and functions 1 3 1 Outside view Operation panel ...
Page 18: ...E6581381 A 6 1 VFFS1 2004 2037PM VFFS1 4004 4055PL Note EMC plate is supplied as standard ...
Page 36: ......
Page 40: ...E6581381 B 4 2 2 2 2 Standard connection diagram 2 ...
Page 54: ......
Page 56: ...E6581381 D 2 4 4 1 Flow of status monitor mode Flow of monitor as following ...
Page 66: ......
Page 180: ......
Page 196: ......
Page 208: ......
Page 233: ...E6581381 L 5 12 Outline drawing Fig A Fig B Fig C Fig D ...
Page 242: ......
Page 248: ......
Page 251: ......