E6581381
F-10
6
(1) A signal is sent out when the two functions assigned are activated simultaneously.
Terminal
symbol
Title
Function
Adjustment range
Default setting
RY-RC
H
Output terminal selection 1A
4 (Low-speed
detection signal)
RY-RC
H
Output terminal selection 1B
0-255
(
⇒
See page K-17)
255 (Always ON)
+
Two different functions can be assigned to terminals RY-RC.
+
If parameter
H
is set to
(default), a signal will be sent out when the two functions assigned are
activated simultaneously.
Terminals RY-RC: Send out a signal when the functions assigned with
H
and
H
are activated
simultaneously.
+
Timing chart
ON
OFF
ON
OFF
ON
OFF
H
H
RY-RC output
+