5. Basic parameters
Before you operate the inverter, the parameters that you must first program are the basic parameters.
5.1
Setting acceleration/deceleration time
CW
:
Automatic acceleration/deceleration
CEE
:
Acceleration time 1
FGE
:
Deceleration time 1
•
Function
1) For acceleration time 1
CEE
programs the time that it takes for the inverter output frequency to go from
0Hz to maximum frequency
HJ
.
2) For deceleration time 1
FGE
programs the time that it takes for the inverter output frequency to got
from maximum frequency
HJ
to 0Hz.
5.1.1 Automatic acceleration/deceleration
This automatically adjusts acceleration and deceleration time in line with load size.
CW
=
* Adjusts the acceleration/deceleration time automatically within the range of 1/8 to 8 times as long as the
time set with the
CEE
or
FGE
, depending on the current rating of the inverter.
CW
=
* Automatically adjusts speed during acceleration only. During deceleration, speed is not adjusted
automatically but reduced at the rate set with
FGE
.
Output
frequency (Hz)
Deceleration
time
Acceleration
time
HJ
When load is small
Time
[sec]
0
Shorten acceleration/deceleration time
Deceleration
time
Acceleration
time
HJ
When load is large
Output
frequency (Hz)
Time
[sec]
0
Lengthen acceleration/deceleration time
Set
CW
(automatic acceleration/deceleration) to
or
.
Summary of Contents for TOSVERT VF-FS1 Series
Page 2: ......
Page 15: ...E6581381 A 3 1 1 3 Names and functions 1 3 1 Outside view Operation panel ...
Page 18: ...E6581381 A 6 1 VFFS1 2004 2037PM VFFS1 4004 4055PL Note EMC plate is supplied as standard ...
Page 36: ......
Page 40: ...E6581381 B 4 2 2 2 2 Standard connection diagram 2 ...
Page 54: ......
Page 56: ...E6581381 D 2 4 4 1 Flow of status monitor mode Flow of monitor as following ...
Page 66: ......
Page 180: ......
Page 196: ......
Page 208: ......
Page 233: ...E6581381 L 5 12 Outline drawing Fig A Fig B Fig C Fig D ...
Page 242: ......
Page 248: ......
Page 251: ......