Item
Specification
Protective function
Stall prevention, current limitation, over-current, output short circuit, over-voltage, over-voltage limitation,
undervoltage, ground fault, power supply phase failure, output phase failure, overload protection by
electronic thermal function, armature over-current at start-up, load side over-current at start-up, over-
torque, undercurrent, overheating, cumulative operation time, life alarm, emergency stop, various pre-
alarms
Electronic thermal
characteristic
Switching between standard motor and constant-torque VF motor, switching between motors 1 and 2,
setting of overload trip time, adjustment of stall prevention levels 1 and 2, selection of overload stall
Pr
ot
ec
tive f
unct
ion
Reset function
Function of resetting by closing contact 1a or by turning off power or the operation panel. This function is
also used to save and clear trip records.
Alarms
Stall prevention, overvoltage, overload, under-voltage, setting error, retry in process, upper/lower limits
Causes of failures
Over-current, overvoltage, overheating, short-circuit in load, ground fault, overload on inverter, over-
current through arm at start-up, over-current through load at start-up, CPU fault, EEPROM fault, RAM
fault, ROM fault, communication error. (Selectable: Emergency stop, under-voltage, low voltage, over-
torque, motor overload, output open-phase)
Monitoring function
Operation frequency, operation frequency command, forward/reverse run, output current, voltage in DC
section, output voltage, torque, torque current, load factor of inverter, input power, output power,
information on input terminals, information on output terminals, version of CPU1, version of CPU2,
version of memory, PID feedback amount, frequency command (after PID), integral input power, integral
output power, rated current, output speed, communication counter, normal state communication counter,
causes of past trips 1 through 4, parts replacement alarm, cumulative operation time
Past trip monitoring
function
Stores data on the past four trips: number of trips that occurred in succession, operation frequency,
direction of rotation, load current, input voltage, output voltage, information on input terminals, information
on output terminals, and cumulative operation time when each trip occurred.
Output for frequency
meter
Analog output: (1mAdc full-scale DC ammeter or 7.5Vdc full-scale DC ammeter / Rectifier-type AC
voltmeter, 225% current Max. 1mAdc, 7.5Vdc full-scale), 4 to 20mA/0 to 20mA output
4-digit 7-segments LED
Frequency:
inverter output frequency.
Alarm:
stall alarm “C”, overvoltage alarm “P”, overload alarm “L”, overheat alarm “H”.
Status:
inverter status (frequency, cause of activation of protective function, input/output voltage,
output current, etc.) and parameter settings.
Free-unit display: arbitrary unit (e.g. rotating speed) corresponding to output frequency.
Display f
unct
ion
Indicator
Lamps indicating the inverter status by lighting, such as RUN lamp, MON lamp, PRG lamp,
%
lamp, Hz
lamp, LOC/REM key lamp, UP/DOWN key lamp and RUN key lamp. The charge lamp indicates that the
main circuit capacitors are electrically charged.
Use environments
Indoor, altitude: 1000m (Max.), not exposed to direct sunlight, corrosive gas, explosive gas or vibration
(less than 5.9m/s
2
) (10 to 55Hz)
Ambient temperature
-10 to +60°C Note1) Note2)
Storage temperature
-20 to +65°C
Envir
onm
en
ts
Relative humidity
20 to 93% (free from condensation and vapor).
Note 1: Above 40°C: Remove the seal from the top of the inverter and use the inverter with the rated output current reduced.
Note 2: If inverters are installed side by side (with no sufficient space left between them): Remove the seal from the top of
each inverter.
When installing the inverter where the ambient temperature will rise above 40°C, remove the seal from the top of the
inverter and use the inverter with the rated output current reduced.
Summary of Contents for TOSVERT VF-FS1 Series
Page 2: ......
Page 15: ...E6581381 A 3 1 1 3 Names and functions 1 3 1 Outside view Operation panel ...
Page 18: ...E6581381 A 6 1 VFFS1 2004 2037PM VFFS1 4004 4055PL Note EMC plate is supplied as standard ...
Page 36: ......
Page 40: ...E6581381 B 4 2 2 2 2 Standard connection diagram 2 ...
Page 54: ......
Page 56: ...E6581381 D 2 4 4 1 Flow of status monitor mode Flow of monitor as following ...
Page 66: ......
Page 180: ......
Page 196: ......
Page 208: ......
Page 233: ...E6581381 L 5 12 Outline drawing Fig A Fig B Fig C Fig D ...
Page 242: ......
Page 248: ......
Page 251: ......