![Toshiba TOSVERT VF-FS1 Series Instruction Manual Download Page 89](http://html.mh-extra.com/html/toshiba/tosvert-vf-fs1-series/tosvert-vf-fs1-series_instruction-manual_425671089.webp)
E6581381
E-23
5
■
Relationship between V/F control mode selection (
RV
) and Motor constant
parameter
&
c
: Valid,
°
: Invalid
Parameter
RV
(V/F control mode selection)
0
1
2
3
4
Title
Function
V/F
constant
Variable
torque
Automatic
torque boost
control
Vector
control
Energy-
saving
XN
Base frequency 1
XNX
Base frequency voltage 1
XD
Torque boost value 1
°
°
°
H
Base frequency 2
c
°
°
°
°
H
Base frequency voltage 2
c
°
°
°
°
H
Torque boost value 2
c
°
°
°
°
H
Auto-tuning
°
°
c
c
c
H
Slip frequency gain
°
°
°
c
°
H
Automatic torque boost value
°
°
H
Motor rated current
c
c
H
Motor no-load current
°
°
c
c
c
H
Motor rated speed
c
c
H
Speed control response coefficient
°
°
c
c
c
H
Speed control stability coefficient
°
°
c
c
c
H
Exciting current coefficient
°
°
c
c
°
H
Stall prevention control coefficient 1
c
c
c
c
c
H
Stall prevention control coefficient 2
c
c
c
c
c
H
Motor adjustment coefficient
c
c
c
c
c
H
Maximum voltage adjustment
coefficient
c
c
c
c
c
H
Waveform switching adjustment
coefficient
c
c
c
c
c
: Be sure to set and adjust the parameters.
c
: Adjust the parameters if necessary.
Summary of Contents for TOSVERT VF-FS1 Series
Page 2: ......
Page 15: ...E6581381 A 3 1 1 3 Names and functions 1 3 1 Outside view Operation panel ...
Page 18: ...E6581381 A 6 1 VFFS1 2004 2037PM VFFS1 4004 4055PL Note EMC plate is supplied as standard ...
Page 36: ......
Page 40: ...E6581381 B 4 2 2 2 2 Standard connection diagram 2 ...
Page 54: ......
Page 56: ...E6581381 D 2 4 4 1 Flow of status monitor mode Flow of monitor as following ...
Page 66: ......
Page 180: ......
Page 196: ......
Page 208: ......
Page 233: ...E6581381 L 5 12 Outline drawing Fig A Fig B Fig C Fig D ...
Page 242: ......
Page 248: ......
Page 251: ......